4.175 dact-cdl

Use this command to deactivate a previously initiated command driven loopback for testing a signaling link, if the test is active. If it is not active, the command will attempt to clear both near-end and far-end latched loopback points

Parameters

link (mandatory)
SS7 signaling ports. The signaling port to which the SS7 signaling link being tested is assigned.
Synonym:
port
Range:
a, b, a1 - a31, b1 - b31

Not all card types support all link parameter values.

See Table A-1 for valid link parameter range values for each type of card that can have assigned signaling links.

loc (mandatory)
The card location as stenciled on the shelf of the system.
Range:
1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118

Example

dact-cdl:loc=1205:link=b

Dependencies

The card location specified in the loc parameter must be equipped.

The signaling link specified in the link parameter must be equipped.

Link Fault Sectionalization (LFS) must not be running on the specified signaling link when this command is entered.

Command Driven Loopback testing is not available during upgrade.

A link diagnostic test is in progress on the signaling link specified in the link parameter, but it is not a Command Driven Loopback.

The card location specified in the loc parameter must be in service.

The signaling link specified in the link parameter must not be active.

The card location specified in the loc parameter cannot be reserved by the system.

Notes

None

Output

dact-cdl:loc=1205:link=b

    tekelecstp 05-01-21 17:00:36 EST  EAGLE5 33.0.0
    Command Accepted: Stop Command Driven Loopback message is sent. 
;

    tekelecstp 05-01-21 17:00:36 EST  EAGLE5 33.0.0
    Command Completed. 
;