4.88 chg-l2t
Use this command to change the values of the SS7 MTP
level 2 timers. The timers are organized in 40 timer sets of which sets 1-35
have 9 timer values and sets 36-40 have 10 timer values. The timer sets are
grouped and system default values are initialized by specification (ANSI, ITU,
High Speed for China, High Speed for Q.703 Annex A, JT Q703, and High Speed for
Unchannelized T1). Each timer set is administered individually by this command.
The
ent-slk
command is used to assign an
SS7 signaling link to any of the timer sets. Each assigned link is associated
with a timer set.
Parameters
- l2tset (mandatory)
- Level 2 timer set. This parameter specifies the Level 2 timer set identifier or timer set number. Up to 40 different timer sets can be defined. A signaling link can be assigned to any of the timer sets.
- nodata (optional)
- This parameter specifies a value for the NODATA
timer.
Note:
The NODATA timer measures the amount of time, in milliseconds, that must pass with no transmissions on a link before the EAGLE interprets the condition as a link failure or terminal equipment failure and initiates changeover procedures.The NODATA timer is not applicable for HSLs. It is valid for low speed links only.
The NODATA timer is configurable only for low speed SS7 links running BASIC Error Correction Method (ECM).
The NODATA timer is not configurable for low speed SS7 links running PCR ECM. The NODATA timer value is calculated as T2 (L2 timer 2 value)/3 for low speed SS7 links running PCR ECM.
- t1 (optional)
- Timer 1—Aligned/ready
- Range:
-
5000 - 350000 (milliseconds)
ANSI timer sets 1–10—5000–20000
ITU timer sets 11–20—40000–50000
China timer sets 21–25—25000–350000
Q.703 Annex A timer sets 26–30—25000–350000
Unchannelized T1 timer sets 31–35—16000–151000
Japan timer sets 36--40--- 15000
- Default:
- No change to the current value
- System Default:
-
ANSI timer sets 1–10—13000
ITU timer sets 11–20—40000
China timer sets 21–25—150000
Q.703 Annex A timer sets 26–30—300000
Unchannelized T1 timer sets 31–35—151000
Japan timer sets 36--40--- 15000
- t2 (optional)
- Timer 2—Not aligned
- Range:
-
5000 - 480000
(milliseconds)
ANSI timer sets 1–10—5000–30000
ITU timer sets 11–20—5000–150000
China timer sets 21–25—5000–150000
Q.703 Annex A timer sets 26–30—5000–150000
Unchannelized T1 timer sets 31–35—5000–14000
Japan timer sets 36--40----5000--480000
- Default:
- No change to the current value
- System Default:
-
ANSI timer sets 1–10—11500
ITU timer sets 11–20—30000
China timer sets 21–25—130000
Q.703 Annex A timer sets 26–30—130000
Unchannelized T1 timer sets 31–35—14000
Japan timer sets 36--40--5000
- t3 (optional)
- Timer 3—Aligned
- Range:
-
1000 - 20000
(milliseconds)
ANSI timer sets 1–10—5000–20000
ITU timer sets 11–20—1000–2000
Q.703 Annex A timer sets 26–30—1000–2000
China timer sets 21–25—1000–2000
Unchannelized T1 timer sets 31–35—5000–14000
Japan timer sets 36--40---3000
- Default:
- No change to the current value
- System Default:
-
ANSI timer sets 1–10—11500
ITU timer sets 11–20—2000
China timer sets 21–25—1000
Q.703 Annex A timer sets 26–30—1000
Unchannelized T1 timer sets 31–35—14000
Japan ITU low speed links 36--40---3000
- t4epp (optional)
- Timer 4—Proving period Emergency
- Range:
-
200 - 10000
(milliseconds)
ANSI timer sets 1–10—200–1000
ITU timer sets 11–20— 400–600
China timer sets 21–25—400–600
Q.703 Annex A timer sets 26–30—400–600
Unchannelized T1 timer sets 31–35—3000–10000
Japan timer sets 36--40--3000
- Default:
- No change to the current value
- System Default:
-
ANSI timer sets 1–10—600
ITU timer sets 11–20—500
China timer sets 21–25—500
Q.703 Annex A timer sets 26–30—500
Unchannelized T1 timer sets 31–35—3000
Japan timer sets 36--40--3000
- t4npp (optional)
- Timer 4— Proving period normal
- Range:
-
500 - 70000
(milliseconds)
ANSI timer sets 1–10—500–5000
ITU timer sets 11–20—7500–9500
China timer sets 21–25—3000–70000
Q.703 Annex A timer sets 26–30—3000–70000
Unchannelized T1 timer sets 31–35—3000–30000
Japan timer sets 36--40-- Not applicable
- Default:
- No change to the current value
- System Default:
-
ANSI timer sets 1–10—2300
ITU timer sets 11–20—8200
China timer sets 21–25—30000
Q.703 Annex A timer sets 26–30—30000
Unchannelized T1 timer sets 31–35—30000
- t5 (optional)
- Timer 5—Sending SIB
- Range:
- 40 - 500
(milliseconds)
ANSI timer sets 1–10—40–500
ITU timer sets 11–20—80–120
China timer sets 21–25—80–120
Q.703 Annex A timer sets 26–30—80–120
Unchannelized T1 timer sets 31–35—80–120
Japan timer sets 36--40--200
- Default:
- No change to the current value
- System Default:
-
ANSI timer sets 1–10—100
ITU timer sets 11–20—100
China timer sets 21–25—100
Q.703 Annex A timer sets 26–30—100
Unchannelized T1 timer sets 31–35—80
Japan timer sets 36--40--200
- t6 (optional)
- Timer 6—Remote congestion
- Range:
- 1000 - 10000
(milliseconds)
ANSI timer sets 1–10—1000 - 10000
ITU timer sets 11–20—3000 - 6000
China timer sets 21–24—3000 - 6000
Q.703 timer sets 26–30—3000 - 6000
Unchannelized T1 sets 31–35—3000 - 6000
Japan timer sets 36--40--5000
- Default:
- No change to the current value
- System Default:
-
ANSI timer sets 1–10—4000
ITU timer sets 11–20—4000
China timer sets 21–25—5000
Q.703 Annex A timer sets 26–30—5000
Unchannelized T1 timer sets 31–35—5000
Japan timer sets 36--40--5000
- t7 (optional)
- Timer 7—Excessive delay of acknowledgment
- Range:
- 200 - 3000
(milliseconds)
For ANSI timer sets 1–10—200–3000
ITU timer sets 11–20—500–2000
China timer sets 21–25—500–2000
Q.703 Annex A timer sets 26–30—500–2000
Unchannelized T1 timer sets 31–35—500–2000
Japan ITU low speed links 36--40---2000--3000
- Default:
- No change to the current value
- System Default:
-
ANSI timer sets 1–10—1500
For ITU timer sets 11–20—1500
For China timer sets 21–25—800
For Q.703 Annex A timer sets 26–30—800
For Unchannelized T1 timer sets 31–35—500
Japan ITU low speed links 36--40--2000
Example
chg-l2t:l2tset=1:t1=5400
chg-l2t:l2tset=21:t4epp=600:t5=90:t6=3500:t7=1900
chg-l2t:l2tset=1:nodata=200
chg-l2t:l2tset=36:t2=6000
Dependencies
At least one optional parameter must be specified.
Failed reading level 2 timer set table.
The value specified for the timer must be within the range for that domain.
The value specified for the timer must be in the allowed range.
For l2tset greater than 35, timers t1, t3, t4epp, t5, and t6 are not allowed to change.
Notes
ANSI timer defaults are within the Telcordia recommended ranges.
ITU timer defaults are within ITU Q.703 white book recommended ranges.
J1 timer defaults are within JT Q.703 white book recommended ranges.
If the value specified for the nodata parameter is greater than 200 milliseconds, then the following message appears:
Caution:
WARNING: If NODATA timer value is greater than 200ms, links could go into congestion before link failure is declaredOutput
chg-l2t:l2tset=21:t4epp=600:t5=90:t6=3500:t7=1900
rlghncxa03w 05-02-07 11:11:28 EST EAGLE5 34.0.0
CHG-L2T: MASP A - COMPLTD
;
chg-l2t:l2tset=1:nodata=200
tekelecstp 08-05-02 16:36:09 EST EAGLE 39.0.0
CHG-L2T: MASP A - COMPLTD