4.521 rtrv-l2t
Use this command to display the values of the SS7 MTP Level 2 timers. The timers are organized in 40 timer sets of 10 timer values each. The timer sets are grouped and system default values are initialized by specification (ANSI, ITU, High Speed for China, High Speed for Q.703 Annex A, JT Q703, and High Speed for Unchannelized T1). Each timer set is administered individually by the chg-l2t
command. The ent-slk command is used to assign an SS7 signaling link to any of the timer sets. Each assigned link is associated with a timer set.
Parameters
Example
rtrv-l2t
rtrv-l2t:l2tset=36
Dependencies
The Level 2 Timer Set table is corrupt or cannot be found.
None.
Notes
The timer values are shown in the output for this command in seconds, even though they were specified in milliseconds in the chg-l2t
command.
Output
The timer values are shown in the output for this command in seconds. rtrv-l2t
tekelecstp 02-01-02 18:39:27 MST EAGLE 46.0.0-65.9.0
rtrv-l2t
Command entered at terminal #3.
;
tekelecstp 02-01-02 18:39:27 MST EAGLE 46.0.0-65.9.0
LEVEL 2 TIMERS (IN SECONDS)
L2TSET T1 T2 T3 T4NPP T4EPP T5 T6 T7 NODATA TE
1 9.0 9.0 9.0 2.3 0.60 0.09 4.0 0.3 0.10 --
2 13.0 11.5 11.5 2.3 0.60 0.10 4.0 1.5 0.10 --
3 13.0 11.5 11.5 2.3 0.60 0.10 4.0 1.5 0.10 --
4 13.0 11.5 11.5 2.3 0.60 0.10 4.0 1.5 0.10 --
5 9.0 9.0 9.0 2.3 0.60 0.10 4.0 0.3 0.10 --
6 13.0 11.5 11.5 2.3 0.60 0.10 4.0 1.5 0.10 --
7 13.0 11.5 11.5 2.3 0.60 0.10 4.0 1.5 0.10 --
8 13.0 11.5 11.5 2.3 0.60 0.10 4.0 1.5 0.10 --
9 9.0 9.0 9.0 2.3 0.60 0.10 4.0 0.3 0.10 --
10 13.0 11.5 11.5 2.3 0.60 0.10 4.0 1.5 0.10 --
11 40.0 30.0 2.0 8.2 0.50 0.10 4.0 1.5 0.10 --
12 49.0 49.0 2.0 8.2 0.50 0.10 4.0 2.0 0.10 --
13 40.0 30.0 2.0 8.2 0.50 0.10 4.0 1.5 0.10 --
14 40.0 30.0 2.0 8.2 0.50 0.10 4.0 1.5 0.10 --
15 40.0 30.0 2.0 8.2 0.50 0.10 4.0 1.5 0.10 --
16 40.0 30.0 2.0 8.2 0.50 0.10 4.0 1.5 0.10 --
17 40.0 30.0 2.0 8.2 0.50 0.10 4.0 1.5 0.10 --
18 40.0 30.0 2.0 8.2 0.50 0.10 4.0 1.5 0.10 --
19 40.0 30.0 2.0 8.2 0.50 0.10 4.0 1.5 0.10 --
20 40.0 30.0 2.0 8.2 0.50 0.10 4.0 1.5 0.10 --
21 150.0 130.0 1.0 30.0 0.50 0.10 5.0 0.8 0.10 --
22 90.0 90.0 2.0 30.0 0.50 0.10 5.0 2.0 0.10 --
23 150.0 130.0 1.0 30.0 0.50 0.10 5.0 0.8 0.10 --
24 150.0 130.0 1.0 30.0 0.50 0.10 5.0 0.8 0.10 --
25 150.0 130.0 1.0 30.0 0.50 0.10 5.0 0.8 0.10 --
26 300.0 130.0 1.0 30.0 0.50 0.10 5.0 0.8 0.10 --
27 300.0 130.0 1.0 30.0 0.50 0.10 5.0 0.8 0.10 --
28 300.0 130.0 1.0 30.0 0.50 0.10 5.0 0.8 0.10 --
29 300.0 130.0 1.0 30.0 0.50 0.10 5.0 0.8 0.10 --
30 300.0 130.0 1.0 30.0 0.50 0.10 5.0 0.8 0.10 --
31 151.0 14.0 14.0 30.0 3.00 0.08 3.0 0.5 0.10 --
32 151.0 14.0 14.0 30.0 3.00 0.08 3.0 0.5 0.10 --
33 151.0 14.0 14.0 30.0 3.00 0.08 3.0 0.5 0.10 --
34 151.0 14.0 14.0 30.0 3.00 0.08 3.0 0.5 0.10 --
35 70.0 7.0 7.0 30.0 3.00 0.12 3.0 2.0 0.10 --
36 15.0 5.0 3.0 -- 3.00 0.20 5.0 2.0 0.10 0.024
37 15.0 5.0 3.0 -- 3.00 0.20 5.0 2.0 0.10 0.024
38 15.0 5.0 3.0 -- 3.00 0.20 5.0 2.0 0.10 0.024
39 15.0 5.0 3.0 -- 3.00 0.20 5.0 2.0 0.10 0.024
40 15.0 5.0 3.0 -- 3.00 0.20 5.0 3.0 0.10 0.024
;
This example displays timer values for a specified timer set: rtrv-l2t:l2tset=36
tekelecstp 02-01-02 18:42:26 MST EAGLE 46.0.0-65.9.0
LEVEL 2 TIMERS (IN SECONDS)
L2TSET T1 T2 T3 T4NPP T4EPP T5 T6 T7 NODATA TE
36 15.0 5.0 3.0 -- 3.00 0.20 5.0 2.0 0.10 0.024
Legend
- L2TSET—SS7 MTP Level 2 timer set identifer or number
- T1—Aligned ready
- T2—Not aligned
- T3—Aligned
- T4NPP—Proving period normal
- T4EPP—Proving period Emergency
- T5—Sending SIB
- T6—Remote congestion
- T7—Excessive delay of acknowledgment
- NODATA—Amount of time with no data
- TE— Error rate monitoring