4.102 chg-meas

Use this command to change both the report and collecting status of the OAM based measurement subsystem.

Note:

After the Measurements Platform collection function has been enabled, the collect=on/off parameter controls only the output of reports to the UI. The parameter has no effect on enabling and disabling collection and report generation for the Measurements Platform. Report generation for the Measurements Platform is controlled by the rept-ftp-meas and chg-measopts commands.

Parameters

collect (optional)
Activates or deactivates the reporting of scheduled measurements to the UI when the E5-OAM Integrated Measurements feature is on. This parameter does not affect measurements collection and generation for the Measurements Platform. It only activates or deactivates the reporting of scheduled measurements to the UI for the Measurements Platform.
Range:
on
off
Default:
No change to value
System Default:
off
complink (optional)
Activates or deactivates scheduled measurement report for links.
Range:
on
off
Default:
Current value
complnkset (optional)
Activates or deactivates scheduled measurement report for linksets.
Range:
on
off
Default:
Current value
gtwylnkset (optional)
Activates or deactivates the scheduled GTWY measurement report for the linkset.
Range:
on
off
Default:
Current value
gtwylsfltr (optional)
Filters the linksets included in the GTWY report.
Range:
both
Only gateway linksets are included in the report to the terminal and SEAS.
stp
Only gateway linksets are included in the report to the terminal. All defined linksets are included in the report to SEAS.
seas
All defined linksets are included in the report to the terminal. Only gateway linksets are included in the report to SEAS.
none
All defined linksets are included in the report to the terminal and SEAS
gtwystp (optional)
Activates or deactivates the scheduled GTWY measurement report for the STP.
Range:
on
off
Default:
Current value
systotstp (optional)
Activates or deactivates scheduled measurement report for STP system totals.
Range:
on
off
Default:
Current value
systottt (optional)
Activates or deactivates scheduled measurement report for translation type system totals.
Range:
on
off
Default:
Current value

Example

chg-meas:collect=on

chg-meas:complink=on:complnkset=on:systottt=off:systotstp=off:collect=on

chg-meas:gtwylsfltr=both

Dependencies

At least one optional parameter must be specified.

If the 15 Minute Measurements and Measurements Platform collection functions are provisioned (see the chg-measopts command), then the collect=on parameter cannot be specified.

At least one SLK or SIP/DEIR connection must be configured before the collect=on parameter is specified.

If the Integrated Measurements feature is turned on and the link count exceeds 700 links, then the systotstp=on, systottt=on, complnkset=on, complink=on, gtwystp=on, or gtwylnkset=on parameter cannot be specified.

Beginning with Release 46.3, basic OAM measurements are not supported. To turn collect=on, either MCPM or integrated measurements should be enabled.

Notes

Activated scheduled reports print at serial ports configured for traffic-related unsolicited messages (the traf=yes parameter of the chg-trm command).

When the Measurements Platform is not enabled, the daily maintenance scheduled reports are always allowed and cannot be inhibited.

Maintenance Guide provides detailed information on measurements and measurement reports.

Output

chg-meas:complink=on:complnkset=on:systottt=off:systotstp=off:collect=on

    rlghncxa03w 04-01-18 17:02:57 EST  EAGLE 31.3.0
    CHG-MEAS: MASP A - COMPLTD 
;