4.102 chg-meas
Use this command to change both the report and collecting status of the OAM based measurement subsystem.
Note:
After the Measurements Platform collection function has been enabled, the collect=on/off parameter controls only the output of reports to the UI. The parameter has no effect on enabling and disabling collection and report generation for the Measurements Platform. Report generation for the Measurements Platform is controlled by therept-ftp-meas
and
chg-measopts
commands.
Parameters
- collect (optional)
- Activates or deactivates the reporting of scheduled measurements to the UI when the E5-OAM Integrated Measurements feature is on. This parameter does not affect measurements collection and generation for the Measurements Platform. It only activates or deactivates the reporting of scheduled measurements to the UI for the Measurements Platform.
- gtwylnkset (optional)
- Activates or deactivates the scheduled GTWY measurement report for the linkset.
- gtwylsfltr (optional)
- Filters the linksets included in the GTWY report.
- Range:
-
- both
- Only gateway linksets are included in the report to the terminal and SEAS.
- stp
- Only gateway linksets are included in the report to the terminal. All defined linksets are included in the report to SEAS.
- seas
- All defined linksets are included in the report to the terminal. Only gateway linksets are included in the report to SEAS.
- none
- All defined linksets are included in the report to the terminal and SEAS
Example
chg-meas:collect=on
chg-meas:complink=on:complnkset=on:systottt=off:systotstp=off:collect=on
chg-meas:gtwylsfltr=both
Dependencies
At least one optional parameter must be specified.
If the 15 Minute Measurements and Measurements Platform
collection functions are provisioned (see the
chg-measopts
command), then the
collect=on parameter cannot be
specified.
At least one SLK or SIP/DEIR connection must be configured before the collect=on parameter is specified.
If the Integrated Measurements feature is turned on and the link count exceeds 700 links, then the systotstp=on, systottt=on, complnkset=on, complink=on, gtwystp=on, or gtwylnkset=on parameter cannot be specified.
Beginning with Release 46.3, basic OAM measurements are not supported. To turn collect=on, either MCPM or integrated measurements should be enabled.
Notes
Activated scheduled reports print at serial ports
configured for traffic-related unsolicited messages (the
traf=yes parameter of the
chg-trm
command).
When the Measurements Platform is not enabled, the daily maintenance scheduled reports are always allowed and cannot be inhibited.
Maintenance Guide provides detailed information on measurements and measurement reports.
Output
chg-meas:complink=on:complnkset=on:systottt=off:systotstp=off:collect=on
rlghncxa03w 04-01-18 17:02:57 EST EAGLE 31.3.0
CHG-MEAS: MASP A - COMPLTD
;
Related Topics