4.171 copy-meas

Use this command to copy all measurements tables on the active fixed disk to a measurements removable drive. Do this when you need to perform off-line analysis of the raw measurements data.

Note:

This command is not supported on the Measurements Platform feature.

Parameters

None

Example

copy-meas

Dependencies

The removable drive:

  • must be inserted
  • must be initialized
  • must be a MEAS disk
  • cannot be a SYSTEM disk

This command cannot be entered when CAT2 IPSM to OAM syncing is in progress.

Notes

To execute this command, measurement collection must be turned off. If measurement collection is on, enter the chg-meas:collect=off command to turn off measurement collection.

The Maintenance Guide provides a description of all measurement report parameters.

To copy the raw measurements data from the active fixed disk to the measurements removable drive requires approximately 2 minutes. This period is the minimum time and is dependent on system activity.

The removable drive must be accessible.

Output

copy-meas

    COPY MEASUREMENTS: MASP A - COPY STARTS ON ACTIVE MASP
    COPY MEASUREMENTS: MASP A - COPY TO REMOVABLE MEDIA COMPLETE 
;