4.107 chg-npp-as

Use this command to change a Numbering Plan Processor (NPP) Action Set (AS). An AS is used by the NPP to assist with digit string filtering, conditioning, and encoding for selected EAGLE applications. An AS is a collection of NPP Conditioning Actions (CAs), Service Actions (SAs), and Formatting Actions (FAs).

Parameters

Note:

CAs and FAs are processed in the order that they are specified in the comma-separated list.

Note:

SAs are processed in order of high-to-low precedence and must be specified in high-to-low precedence order in the comma-separated list. The SAs cannot be duplicated in the list. If multiple SAs have the same precedence, then the SAs are processed in the order in which they appear in the list.

Note:

CAs and FAs are processed in consecutive order. The CAs and FAs are processed in the order that they are specified in the comma separated list.

Note:

SAs are processed in order of high-to-low precedence. The SAs must be specified in high-to-low precedence order in the list, and cannot be duplicated in the comma separated list. If multiple SAs have the same precedence, then the SAs are processed in the order in which they appear in the list.

Note:

The ac*, dn*, sn*, and cc* values refer to all CAs that begin with ac, dn, sn, or cc, respectively.

Note:

To change the value of a single CA, FA, or SA within an AS, all of the associated parameters that were specified for that CA, FA, or SA for the AS must be entered.

Note:

Refer to Numbering Plan Processor (NPP) User's Guide and to the Feature Manual for the feature of interest for more information on provisioning Action Sets and for definitions for the CA, FA, and SA values.

Note:

The sa(X)dgts parameters are currently not supported by any feature.

Note:

The sa(X)val parameters are used by the TIF Range CgPN Blacklist, TIF Subscriber CgPN Blacklist, and TIF Selective Screening features. Up to 2 numerical values can be specified in each list.

Note:

If an sa(X) value is changed or removed, then any associated sa(X)val and sa(X)dgts parameters are set to none unless a new value is specified in the command.

Note:

Support of a numerical values list (sa(X)val parameter) is specific to the Service and Service Action.
asn (mandatory)
Action set name. This parameter specifies the name of the AS.
Range:
ayyyyyyyyy

1 alphabetic character followed by up to 9 alphanumeric characters

ca (optional)
Conditioning Action list. A comma-separated CA list that can be applied to an incoming digit string. Up to 12 CAs can be specified in the list. The CAs are processed in the order they are specified in the list.
Range:
ac1, ac2, ac3, ac4, ac5, ac6, ac7, ac8, accgpn, accgpn1, accgpn2, accgpn3, accgpn4, accgpn5, accgpn6, accgpn7, accgpn8, acdef, aclac, cc1, cc2, cc3, ccdef, cccgpn, dn1, dn2, dn3, dn4, dn5, dn6, dn7, dn8, dn9, dn11, dn12, dn13, dn14, dn15, dnx, fpfx, ign1, ign2, ign3, ign4, ign5, ign6, ign7, ign8, ign9, ign10, pfxa1, pfxa2, pfxa3, pfxa4, pfxa5, pfxa6, pfxa7, pfxa8, pfxb1, pfxb2, pfxb3, pfxb4, pfxb5, pfxb6, pfxb7, pfxb8, pfxc1, pfxc2, pfxc3, pfxc4, pfxc5, pfxc6, pfxc7, pfxc8, pfxd1, pfxd2, pfxd3, pfxd4, pfxd5, pfxd6, pfxd7, pfxd8, pfxe1, pfxe2, pfxe3, pfxe4, pfxe5, pfxe6, pfxe7, pfxe8, pfxf1, pfxf2, pfxf3, pfxf4, pfxf5, pfxf6, pfxf7, pfxf8, sn1, sn2, sn3, sn4, sn5, sn6, sn7, sn8, sn9, sn10, sn11, sn12, sn13, sn14, sn15, snx, znx
fa (optional)
Formatting Action list. A comma-separated FA list that can be applied to the outgoing digit string. Up to 12 FAs can be specified in the list. The FAs are processed in the order they are specified in the list and cannot be duplicated.
Range:
ac, asd, asdother, cc, dlma, dlmb, dlmc, dlmd, dlme, dlmf, dlmg, dlmh, dlmi, dlmj, dlmk, dlml, dlmm, dlmn, dlmo, dlmp, dn, fpfx, grn, grnother, orig, pfxa, pfxb, pfxc, pfxd, pfxe, pfxf, rn, rnospodn, rnosposn, rnospozn, sn, sp, sfrimsi, vmid, zn, none

none-deletes all FAs from the specified FA list

fatype (optional)

Formatting Action List Type. The Formatting Action list used to format digits in response messages on a per message basis. The lists are updated by values specified for the fa parameter.

Range:
dflt
digits are formatted using the TTROPTS:CDDRA and TTROPTS:CGDRA parameters
fane
Formatting Action list to format digits when neither the SP nor the RN network entity is associated with the DN in the RTDB
fanf
Formatting Action list to format digits when the DN is not present in the RTDB
farn
Formatting Action list to format digits when the RN network entity is associated with the DN in the RTDB
fasp
Formatting Action list to format digits when the SP network entity is associated with the DN in the RTDB
fascrcd
Formatting Action list to format ISUP CdPN digits when CdPN is Screened by SELSCR SA and SA(X)VAL is none.
fascrcg
Formatting Action list to format ISUP CgPN digits when CdPN is Screened by SELSCR SA and SA(X)VAL is none.
ofnai (optional)
Outgoing filter nature of address indicator. The filter nature of address indicator (FNAI) class of the outgoing digit string.
Range:
intl
intl value provisioned in the chg-npp-serv command
natl
natl value provisioned in the chg-npp-serv command
nai1
nai1 value provisioned in the chg-npp-serv command
nai2
nai2 value provisioned in the chg-npp-serv command
nai3
nai3 value provisioned in the chg-npp-serv command
unkn
unkn value provisioned in the chg-npp-serv command
inc
NAI of the incoming digit string
sa (optional)
Service Action list. A comma-separated SA list that can be applied to an incoming digit string. Up to 8 SAs can be specified in the list. The SAs must be specified in high-to-low precedence order in the list, and cannot be duplicated in the list.
Range:
asdlkup, blklstqry, blklstrly, blnfndrls, blrls, cdial, ccncchk, cdpnnp, cgpnasdrqd, cgpngrnrqd, cgpnnp, cgpnrtg, cgpnsvcrqd, crp, fpfxrls, fraudchk, fwdscs, grnlkup, inprtg, lacck, migrate, nocgpnrls, npnrls, nprelay, nprls, nscgpn, nscdpn, pprelay, rtdbtrn, rtdbtsp, rtdbtrnsp, skgtartg, snscgpn, tifgnbl, tiflsbl, tifrdnbl

none— Deletes ALL SAs from the Action Set.

sa1dgts (optional)
Service Action 1 digit string. A digit string that can be used with the first SA.
Range:
1-8 hexadecimal digits.  Valid digits are 0-9, a-f, A-F.

none –Deletes digit string for this SA

sa1val (optional)
Service Action 1 numerical values list. A comma-separated numerical values list that can be used with the first SA.
Range:
0 - 65534, none

none —Deletes all numerical values for this SA from list

sa2dgts (optional)
Service Action 2 digit string. A digit string that can be used with the second SA.
Range:

1-8 hexadecimal digits.  Valid digits are 0-9, a-f, A-F

none –Deletes digit string for this SA

sa2val (optional)
Service action 2 numerical values list. A comma-separated numerical values list that can be used with the second SA. 
Range:
0 - 65534, none

none—Deletes all numerical values for this SA from list

sa3dgts (optional)
Service Action 3 digit string. A digit string that can be used with the third SA.
Range:

1-8 hexadecimal digits.  Valid digits are 0-9, a-f, A-F

none—Deletes digit string for this SA

sa3val (optional)
Service Action 3 numerical values list. A comma-separated numerical values list that can be used with the third SA.
Range:
0 - 65534, none

none-Deletes all numerical values for this SA from list

sa4dgts (optional)
Service Action 4 digit string. A digit string that can be used with the fourth SA.
Range:

1-8 hexadecimal digits, none 

Valid digits are 0-9, a-f, A-F

none—Deletes digit string for this SA

sa4val (optional)
Service Action 4 numerical values list. A comma-separated numerical values list that can be used with the fourth SA.
Range:
0 - 65534, none

none—Deletes all numerical values for this SA from list

sa5dgts (optional)
Service Action 5 digit string. A digit string that can be used with the fifth SA.
Range:

1-8 hexadecimal digits, none 

Valid digits are 0-9, a-f, A-F

none—Deletes digit string for this SA

sa5val (optional)
Service Action 5 numerical values list. A comma-separated numerical values list that can be used with the fifth SA. 
Range:
0 - 65534, none

none —Deletes all numerical values for this SA from list

sa6dgts (optional)
Service Action 6 digit string. A digit string that can be used with the sixth SA.
Range:

1-8 hexadecimal digits, none 

Valid digits are 0-9, a-f, A-F

none—Deletes digit string for this SA

sa6val (optional)
Service Action 6 numerical values list. A comma-separated numerical values list that can be used with the sixth SA.
Range:
0 - 65534, none

none—Deletes all numerical values for this SA from list

sa7dgts (optional)
Service Action 7 digit string. A digit string that can be used with the seventh SA.
Range:

1-8 hexadecimal digits, none

Valid digits are 0-9, a-f, A-F

none—Deletes digit string for this SA

sa7val (optional)
Service Action 7 numerical values list. A comma-separated numerical values list that can be used with the seventh SA.
Range:
0 - 65534, none

none—Deletes all numerical values for this SA from list

sa8dgts (optional)
Service Action 8 digit string. A digit string that can be used with the eighth SA.
Range:

1-8 hexadecimal digits, none

Valid digits are 0-9, a-f, A-F

none—Deletes digit string for this SA

sa8val (optional)
Service Action 8 numerical values list. A comma-separated numerical values list that can be used with the eighth SA.
Range:
0 - 65534, none

none—Deletes all numerical values for this SA from list

Example

chg-npp-as:asn=asn7:ca=ign1,ac1,cc3,sn2:fa=cc,sn,ac

chg-npp-as:asn=asn7:ca=cc1,dn1:fa=cc,dn

chg-npp-as:asn=asn1:ca=znx:fa=asd:sa=cgpnasdrqd

chg-npp-as:asn=asn8:ca=cc2,dnx:fa=cc,rnospodn

chg-npp-as:asn=asn9:sa=migrate,asdlkup

chg-npp-as:asn=asn6:ca=znx:fa=zn:sa=nscdpn,nscgpn

chg-npp-as:asn=set10:sa=blrls,blnfndrls,nscgpn:sa1val=101,102:sa2val=77,88

chg-npp-as:asn=asn9:ca=znx:sa=inprtg=skgtartg

chg-npp-as:asn=set32:ca=ccdef,accgpn2,snx

chg-npp-as:asn=asn1:fa=cc,ac,grn,sn:fatype=fane

chg-npp-as:asn=asn1:fa=none:fatype=fasp

chg-npp-as:asn=tif5557:fa=dlma,zn:fatype=fascrd

chg-npp-as:asn=tif1:fa=dlma,zn:sa1va1=10,none:sa1dgt=ff:fatype=fascrcd

chg-npp-as:asn=set1:ca=znx:sa=tifgnbl

Dependencies

One of the following combinations of Conditioning Actions must be specified:

  • znx
  • cc*, dn*
  • cc*, ac*, sn*

The existing or new Formatting Actions specified for the AS must contain the corresponding Formatting Action that a Conditioning Action will populate or load.

The AS must contain a CA that can load or populate all the Formatting Action lists configured in the AS.

The CAs within an AS cannot condition more than 32 digits.

The AS cannot contain CAs that load or populate the same FA.

Conditioning Actions must be specified for inclusion in an individual Action Set using valid number conditioning rules:

  • If the ZNX Conditioning Action is specified, then the CC*, AC*, SN*, DN*, and DNX Conditioning Actions cannot be specified.
  • If the CC* AND DN* or DNX Conditioning Actions are specified, then the AC*, SN*, SNX, and ZNX Conditioning Actions cannot be specified.
  • If the CC*, AC*, AND SN* or SNX Conditioning Actions are specified, then the DN*, DNX, and ZNX Conditioning Actions cannot be specified.

The AS cannot contain the following combinations of FAs:

  • If the DN Formatting Action is specified, then the AC, SN, and ZN Formatting Actions cannot be specified.
  • If the ZN Formatting Action is specified, then the AC, CC, SN, and DN Formatting Actions cannot be specified.
  • If the SN Formatting Action is specified, then the ZN and DN Formatting Actions cannot be specified.
  • If the RNOSPODN, RNOSPOSN, or RNOSPOZN Formatting Action is specified, then the RN, SP, SN, DN, and ZN Formatting Actions cannot be specified.
  • The RNOSPODN, RNOSPOSN, and RNOSPOZN Formatting Actions cannot be specified together.

Note:

This rule is applicable for FA lists FANE, FANF, FARN, and FASP as well.

If specified, the FPFX CA must be the first value (fpfx) in the ca value list.

If specified, the ZNX, SNX, or DNX CA must be the final value (znx, snx, or dnx) in the ca value list.

If rules that reference an AS exist, then the AS cannot be changed.

The ca and caX, fa and faX, and sa and saX  parameters cannot be specified together in the command.

The fa parameter must be specified before the fatype parameter can be specified.

The AS specified by the asn parameter must already exist.

If no Service Actions are provisioned, then only a value of none can be specified for the sa1val parameter.

If less than 2 Service Actions are provisioned, then only a value of none can be specified for the sa2val parameter.

If less than 3 Service Actions are provisioned, then only a value of none can be specified for the sa3val parameter.

If less than 4 Service Actions are provisioned, then only a value of none can be specified for the sa4val parameter.

If less than 5 Service Actions are provisioned, then only a value of none can be specified for the sa5val parameter.

If less than 6 Service Actions are provisioned, then only a value of none can be specified for the sa6val parameter.

If less than 7 Service Actions are provisioned, then only a value of none can be specified for the sa7val parameter.

If less than 8 Service Actions are provisioned, then only a value of none can be specified for the sa8val parameter.

If no Service Actions are provisioned, then only a value of none can be specified for the sa1dgts parameter.

If less than 2 Service Actions are provisioned, then only a value of none can be specified for the sa2dgts parameter.

If less than 3 Service Actions are provisioned, then only a value of none can be specified for the sa3dgts parameter.

If less than 4 Service Actions are provisioned, then only a value of none can be specified for the sa4dgts parameter.

If less than 5 Service Actions are provisioned, then only a value of none can be specified for the sa5dgts parameter.

If less than 6 Service Actions are provisioned, then only a value of none can be specified for the sa6dgts parameter.

If less than 7 Service Actions are provisioned, then only a value of none can be specified for the sa7dgts parameter.

If less than 8 Service Actions are provisioned, then only a value of none can be specified for the sa8dgts parameter.

Notes

None.

Output

chg-npp-as:asn=asn7:ca=cc1,dn1:fa=cc,dn

    tekelecstp 09-08-18 13:57:06 EST  EAGLE 41.1.0
    NPP-AS   table is (5 of 1024) 1% full.

    CHG-NPP-AS: MASP A - COMPLTD 
;