4.165 clr-imt-stats

Every card in the system has a card location identifier (stenciled on the shelf and provided in all output) and an IMT address. Use this command to clear the following statistics:

  • IMT level 1 and level 2 statistics for specified IMT addresses and hourly time period statistics for IMT errors
  • Card error and hourly time period statistics for the MUX cards
  • All IMT and MUX error and hourly time period statistics. When hourly time period statistics for the errors are cleared, the current hourly time period number is reset to 0 (zero) on all cards.

Parameters

all (optional)
Clear all IMT and MUX statistics.
Range:
yes
no
Default:
no
e (optional)
End address. The IMT address of the last card in the range.
Range:
0 - 251

(See the Installation Guide for an illustration with IMT addresses).

eloc (optional)
End location. The card location of the last card in the range.
Range:
1101 - 1113, 1115, 1201 - 1218, 1301 - 1318, 2101 - 2118, 2201 - 2218, 2301 - 2318, 3101 - 3118, 3201 - 3218, 3301 - 3318, 4101 - 4118, 4201 - 4218, 4301 - 4318, 5101 - 5118, 5201 - 5218, 5301 - 5318, 6101 - 6118
Default:
If sloc is specified—current sloc value

If sloc is not specified—1115 which corresponds to IMT address 251 ( e=251)

eshelf (optional)
End shelf location for MUX statistics. The shelf location of the last shelf in the range. (MUX statistics will be cleared if they exist in the range between and including the sshelf and eshelf locations).
Range:
1100, 1200 - 6100
Default:
If sshelf is specified—current sshelf value

If sshelf is not specified— 6100

s (optional)
Start address. The IMT address of the first (or only) card in the range.
Range:
0 - 251

See the Installation Guide of your current documentation set for an illustration with IMT addresses.

sloc (optional)
Start location. Specifies the card location of the first card in the range.
Range:
1101 - 1113, 1115, 1201 - 1218, 1301 - 1318, 2101 - 2118, 2201 - 2218, 2301 - 2318, 3101 - 3118, 3201 - 3218, 3301 - 3318, 4101 - 4118, 4201 - 4218, 4301 - 4318, 5101 - 5118, 5201 - 5218, 5301 - 5318, 6101 - 6118
Default:
If eloc is specified—current eloc value

If eloc is not specified— 1201 which corresponds to IMT address 0 (s=0).

sshelf (optional)
Start shelf location for MUX statistics. This parameter specifies the shelf location of the first shelf in the range. (MUX statistics will be cleared if they exist in the range between and including the sshelf and eshelf locations).
Range:
1100, 1200 - 6100
Default:
If eshelf is specified—current eshelf value

If eshelf is not specified— 1100

Example

clr-imt-stats:s=00

Dependencies

The command cannot be entered if the rept-imt-info, rept-imt-lvl1, rept-imt-lvl2, or tst-imt command is running.

The s and e parameters and the sloc and eloc parameters cannot be specified in the same command.

This command cannot be entered during IMT statistics collection following an hourly boundary.

The s, sloc, or shelf parameter must be specified.

This command cannot be entered during an Extended Bit Error Rate Test (BERT).

Notes

The sloc and eloc parameters allow individual MUX cards to be cleared.

The s and e parameters will not clear MUX cards.

The sshelf and eshelf parameters clear MUX cards on bus A and bus B.

Output

clr-imt-stats:all=yes

    rlghncxa03w 04-01-07 11:02:30 EST  EAGLE 35.0.0
    Clear IMT Statistics command(s) issued...