4.165 clr-imt-stats
Every card in the system has a card location identifier (stenciled on the shelf and provided in all output) and an IMT address. Use this command to clear the following statistics:
- IMT level 1 and level 2 statistics for specified IMT addresses and hourly time period statistics for IMT errors
- Card error and hourly time period statistics for the MUX cards
- All IMT and MUX error and hourly time period statistics. When hourly time period statistics for the errors are cleared, the current hourly time period number is reset to 0 (zero) on all cards.
Parameters
- eloc (optional)
- End location. The card location of the last card in the range.
- Range:
- 1101 - 1113, 1115, 1201 - 1218, 1301 - 1318, 2101 - 2118, 2201 - 2218, 2301 - 2318, 3101 - 3118, 3201 - 3218, 3301 - 3318, 4101 - 4118, 4201 - 4218, 4301 - 4318, 5101 - 5118, 5201 - 5218, 5301 - 5318, 6101 - 6118
- Default:
- If sloc is specified—current sloc value
If sloc is not specified—1115 which corresponds to IMT address 251 ( e=251)
- eshelf (optional)
- End shelf location for MUX statistics. The shelf location of the last shelf in the range. (MUX statistics will be cleared if they exist in the range between and including the sshelf and eshelf locations).
- sloc (optional)
- Start location. Specifies the card location of the first card in the range.
- Range:
- 1101 - 1113, 1115, 1201 - 1218, 1301 - 1318, 2101 - 2118, 2201 - 2218, 2301 - 2318, 3101 - 3118, 3201 - 3218, 3301 - 3318, 4101 - 4118, 4201 - 4218, 4301 - 4318, 5101 - 5118, 5201 - 5218, 5301 - 5318, 6101 - 6118
- Default:
- If eloc is specified—current eloc value
If eloc is not specified— 1201 which corresponds to IMT address 0 (s=0).
Example
clr-imt-stats:s=00
Dependencies
The command cannot be entered if the rept-imt-info, rept-imt-lvl1, rept-imt-lvl2
, or tst-imt
command is running.
The s and e parameters and the sloc and eloc parameters cannot be specified in the same command.
This command cannot be entered during IMT statistics collection following an hourly boundary.
The s, sloc, or shelf parameter must be specified.
This command cannot be entered during an Extended Bit Error Rate Test (BERT).
Notes
The sloc and eloc parameters allow individual MUX cards to be cleared.
The s and e parameters will not clear MUX cards.
The sshelf and eshelf parameters clear MUX cards on bus A and bus B.
Output
clr-imt-stats:all=yes
rlghncxa03w 04-01-07 11:02:30 EST EAGLE 35.0.0
Clear IMT Statistics command(s) issued...
Command Completed.
;