4.371 inh-card

Use this command to change the state of the card from in-service normal (IS-NR) to Out-of-Service Maintenance-Disabled (OOS-MT-DSBLD). A user can then test the card or physically remove it from the shelf.

Parameters

eloc (optional)
End location. The location of the last card of a range of cards to be inhibited.
Range:
1101 - 1108, 1111 - 1113, 1115, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
force (optional)
Force indicator. This parameter is required if:
  • The specified card is the last card supporting a linkset, SCCP subsystem, MPS-to-Service Module connection, E1, T1, Measurements Platform subsystem, or GLS
  • The TDM contains a security log with un-uploaded entries or any other TDM process in progress
  • The specified E5-E1T1-B card is in channel bridging mode
  • The specified card has the last in-service SEAS terminal configured.
Range:
yes
no
Default:
no

Note:

If the force parameter is specified in the command along with the sloc and eloc parameters, then the force parameter's value is applied to all the cards within the sloc-eloc range, including sloc and eloc.
loc (optional)
Card address. The card location as stenciled on the shelf of the system.
Range:
1101 - 1108, 1111 - 1113, 1115, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
sloc (optional)
Start location. The location of the first card of a range of cards to be inhibited.
Range:
1101 - 1108, 1111 - 1113, 1115, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118

Example

inh-card:loc=1101

inh-card:loc=1201:force=yes

inh-card:sloc=1101:eloc=1111

inh-card:sloc=1101:eloc=1111:force=yes

Dependencies

No other action commands can be in progress when this command is entered.

TDM and MDAL cards cannot be inhibited. E5-APP-B cards and Telco Switches cannot be inhibited. Card locations 1114, 1116, 1117, xx09, and xx10 cannot be specified as values for the loc parameter.

If the card contains signaling or data links, all links must be out of service (OOS-MT-DSBLD) before the card can be inhibited.

If the card is type LIME1, all signaling links providing timeslots serviced by the E1 interfaces assigned to the card must be deactivated, unless force=yes is specified.

If the card is type LIMT1, all signaling links providing timeslots serviced by the T1 interfaces assigned to the card must be deactivated, unless force=yes is specified.

The shelf and card must be equipped.

If the specified card is the only in-service MPS-Service Module, the force=yes parameter must be specified.

If inhibiting the Service Module card would cause less than 80% of the in-service normal (IS-NR) LIM cards to have VSCCP service (i.e., cause the system to enter an unstable loading mode), the force=yes parameter must be specified.

If the Integrated GLS feature is turned OFF and the specified card is only GLS card remaining, then the force=yes parameter is required.

The card that is specified by the loc/sloc/eloc parameter cannot be running the active OAM.

If the specified card has the last in-service SEAS Terminal configured, then the force=yes parameter must be specified to inhibit the card.

The card location (loc) must be within the allowed range.

The standby fixed disk cannot be initialized while un-uploaded security log entries exist.

The loc parameter cannot be specified with the eloc and sloc parameters.

Either the loc parameter or the eloc and sloc parameters must be specified.

The eloc and sloc parameters must be specified together in the command.

The sloc parameter value cannot be greater than the eloc parameter value.

The inh-card command cannot be issued when SFAPP(P)->OAM sync is ON.

This command cannot be entered when CAT2 IPSM to OAM syncing is in progress.

Notes

The function of this command is the same as the rmv-card command.

When this command is entered, the card is initialized and enters the OOS-MT-DSBLD state. It has no affect if the card is already OOS-MT-DSBLD.

Caution:

This command can be used to disable Measurements Platform measurements collection after the collection function has been enabled with the chg-measopts:platformenable=on command. To disable collection, ALL MCPM cards in the system must be inhibited. THIS CAN RESULT IN LOSING ALL PAST MEASUREMENT DATA ON THE CARDS. Use the alw-card command to enable measurements collection after the MCPM cards have been inhibited.

When an IPSM card is inhibited, the active SEAS terminals are set to the state OOS-MT/FLT.

Output

inh-card:loc=1101

    rlghncxa03w 04-01-07 11:11:28 EST  EAGLE 31.3.0
    Card has been inhibited. 
;
inh-card:sloc=1101:eloc=1107

Command Accepted - Processing

    tekelecstp 15-04-22 16:52:31 MST  EAGLE5 47.0.0-66.1.0
    inh-card:sloc=1101:eloc=1107
    Command entered at terminal #4.
;

    tekelecstp 15-04-22 16:52:31 MST  EAGLE5 47.0.0-66.1.0
    inh-card command for location 1101-1107 Started
;

    tekelecstp 15-04-22 16:52:31 MST  EAGLE5 47.0.0-66.1.0
    LOC 1101: INHIBIT OPERATION COMPLETED
    LOC 1103: INHIBIT OPERATION COMPLETED
    LOC 1105: INHIBIT OPERATION COMPLETED
    LOC 1107: INHIBIT OPERATION COMPLETED
    ALL CARDS HAVE BEEN INHIBITED
    inh-card command for location 1101-1107 Completed
;

    tekelecstp 15-04-22 16:52:31 MST  EAGLE5 47.0.0-66.1.0
    Command Completed.
;