4.379 init-imt-gpl

Use this command to load the specified IMT GPL software to the specified card and to reset that card. The application software is reloaded following IMT reset.

Parameters

code (mandatory)
The IMT GPL to load to the card.
Range:
appr
The approved GPL version
refresh
Reload approvedl GPL version without card reset
trial
The trial GPL version
loc (optional)
The location of the card to be initialized.
Range:
1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
Default:
All locations

Example

init-imt-gpl:loc=1201:code=trial

init-imt-gpl:code=refresh

init-imt-gpl:code=appr

Dependencies

The card location shelf must be within the allowed ranges as specified on the loc parameter. The shelf is the first two digits of the loc parameter.

The card location slot must be within the allowed ranges as specified on the loc parameter. The slot is the second two digits of the loc parameter.

The card location cannot contain a card with flash memory (MUX).

When this command is entered, no other action command can be in progress.

If the code=appr or code=trial parameter is specified, the loc parameter must be specified.

If the code=trial parameter is specified, the loc parameter must be specified, and the specified card location must be equipped and in service.

If the code=appr or code=refresh parameter is specified, the card must be connected to at least one IMT bus and communicating with the active MASP when the command is entered.

This command cannot be entered if the clr-imt-stats, rept-imt-info, rept-imt-lvl1, rept-imt-lvl2, or tst-imt command is running.

This command must not be entered during IMT statistics collection following an hourly boundary.

A card location that is valid and defined in the database must be specified.

This command cannot be entered during an Extended Bit Error Rate Test (BERT).

Notes

None

Output

init-imt-gpl:loc=1201:code=trial

    rlghncxa03w 04-02-27 16:53:22 EST   EAGLE 31.3.0
    Initializing IMT GPL for card 1201.

    rlghncxa03w 04-02-27 16:53:22 EST   EAGLE 31.3.0 
*   0192.0013  * CARD 1201 SS7ANSI     Card is isolated from the system

    rlghncxa03w 04-02-27 16:53:22 EST   EAGLE 31.3.0
    0193.0014    CARD 1201 SS7ANSI     Card is present

    rlghncxa03w 04-02-27 16:53:22 EST   EAGLE 31.3.0
    0194.0096    CARD 1201 SS7ANSI     Card has been reloaded 
;