4.380 init-mux
This command is used to reset an individual MUX card, or a given IMT Bus A or B (which includes all MUX cards for that bus).
The command boots the MUX card processor and brings down the respective IMT bus temporarily (approximately 10 seconds) until the MUX card(s) come back into service.
Note:
When a card is disconnected from the IMT Bus, it may take several seconds for the card IMT Status to be updated. If aninit-mux
or disc-imt
command is entered for the alternate IMT Bus before the card IMT Status is updated, then the card may reboot. After disconnecting the card from the IMT bus, use the rept-stat-imt
or rept-stat-card
command to determine whether the card IMT status is updated. Do not issue the disc-imt
or init-mux
command for the alternate IMT bus until the card status is updated.
Parameters
- force (optional)
- This parameter is specified to override normal safeguards. The force=yes parameter can be used to reset an entire MUX bus when the alternate bus is non-functional or to reset one MUX card during a fault isolation test (see the
tst-imt
command).Caution:
If the force=yes parameter is specified, and the alternate IMT bus is OOS, then all of the cards on the IMT that are running a GPL will initialize. If one or more cards are not aligned on the alternate bus, placing the alternate IMT in IS-ANR, only the non-aligned cards will initialize. Either occurrence could result in nodal isolation.
Example
init-mux:bus=a
init-mux:bus=a:hs=no
init-mux:loc=1109
init-mux:loc=6202
Dependencies
An act/init-flash
command cannot be in progress when this command is entered.
The bus or loc parameter must be specified in the command. Both parameters cannot be specified in the command.
The hs parameter can be specified only when the bus parameter is specified.
The force=yes parameter must be specified before this command can be entered during an IMT Fault Isolation test.
This command cannot be entered during an Extended Bit Error Rate Test (BERT) even if the force=yes parameter is specified.
This command is not allowed during the IMT statistics collection period following an hourly boundary (IMT performance monitoring).
This command cannot be entered if an IMT Rate Change sequence is in progress.
If one or more cards are not aligned on the alternate bus, the alternate IMT state will become IS-ANR. If the alternate bus is IS-ANR, then the force=yes parameter must be specified.
Notes
The hs parameter should be specified only as a tool to facilitate updating spare cards for releases that support MUX bus speeds of 2.5 Gbps only. The hs parameter is persistent as long as the card remains powered. If the card loses power, it will default back to 2.5 Gbps.
Output
init-mux:loc=1109
rlghncxa03w 05-07-13 08:15:10 EST EAGLE 31.3.0
Command Completed.
;