4.6 act-flash
Use this command to activate the trial FLASH GPL that is currently running on one target card or on a range of cards.
Parameters
- gpl (optional)
- Generic program load. The flash GPL type that is
running on the cards in the specified range of cards.
Note:
This parameter must be specified for cards that have more than one flash image (GPL).
Example
act-flash:loc=1105
act-flash:sloc=1101:eloc=1112:gpl=blmcap
Dependencies
The card, or cards, in the specified location or range of locations for this command must be actively running a flash GPL in trial mode.
The allowed cards are E5-ENET-B, E5-E1T1-B, E5-MCAP, or Service Module. Card locations xy09 and xy10 (x is the frame, y is the shelf) can be specified only for MUX cards.
Each specified card does not have to be defined in the database, but it does have to be aligned on the IMT bus.
If the target card is a MUX card, then both card locations specified in the sloc and eloc parameters must contain MUX cards on the same IMT bus. For these cards, the bus is implicit based on the specified location. Location xy09 specifies a MUX A Bus, and location xy10 specifies a MUX B Bus (x is the frame and y is the shelf). For example, sloc=1109:eloc=6109 specifies all MUX cards on the A Bus only; sloc=1110:eloc=6110 specifies all MUX cards on the B Bus only. MUX cards from both the A bus and B bus cannot be flash downloaded simultaneously.
The card must be running an inactive flash GPL when this command is executed.
The provisioning subsystem mode (simple, duplex) must be established prior to executing the command.
The loc parameter cannot be specified with the eloc and sloc parameters.
Either the loc parameter or the eloc and sloc parameters must be specified.
The eloc and sloc parameters must be specified together in the command; one parameter cannot be specified without the other parameter.
The sloc parameter value cannot be greater than the eloc parameter value.
MUX cards in the specified sloc and eloc card locations must be present and able to communicate over the IMT. The cards do not have to be provisioned in the database.
The gpl parameter must be specified if the eloc and sloc parameters are specified.
The gpl parameter must be specified for cards that have more than one flash image (GPL).
MUX cards in the locations specified by the sloc and eloc parameters must be running the specified GPL. If the GPL specified is not multiple, then other cards in the range of locations can be running other GPLs but will not be activated, and only cards that are within the range and running the specified GPL will be activated.
A card that is the active MASP cannot be specified for the loc, sloc, or eloc parameter.
No other action command can be in progress when this command is entered.
A card location that is valid and defined in the database must be specified.
MUX cards specified in the sloc and eloc location parameters must be running the specified general program load (gpl). For other GPLs including multiple, all cards within the range running the specified GPL will be activated.
This command cannot be entered during an Extended Bit Error Rate Test (BERT).
The gpl=multiple parameter can be specified only if the sloc and eloc parameters are specified.
The gpl=multiple parameter can be specified only if the cards in the locations specified in the sloc and eloc parameters are E5-class cards.
Notes
None
Output
act-flash:loc=1105
rlghncxa03w 04-01-04 13:05:05 EST EAGLE 31.3.0
FLASH Memory Activation for card 1105 Started.
;
rlghncxa03w 04-01-04 13:05:05 EST EAGLE 31.3.0
FLASH Memory Activation for card 1105 Completed.
;
rlghncxa03w 04-01-04 13:05:05 EST EAGLE 31.3.0
Command Completed.
;
act-flash:sloc=1101:eloc=1112:gpl=blmcap
tekelecstp 18-01-15 02:30:23 EST EAGLE 46.6.0.0.0-71.5.0
FLASH activation for cards 1101 - 1112 Completed.
LOC 1101 : PASSED
LOC 1102 : PASSED
LOC 1112 : PASSED
ALL CARD RESULTS PASSED
;
Command Completed.
;