4.418 rept-stat-meas

Use this command to report the status of the Measurements Subsystem (Measurements Platform) or MASPs (Integrated Measurements), including card location and state, IP link status, alarm level, and subsystem state.

Note:

If the Integrated Measurements collection function is turned on, then the status reflects the state of the E5-OAM card(s). If the Measurements Platform collection function is turned on, then the status reflects the state of the MCPM cards.

Parameters

This command has no parameters.

Example

rept-stat-meas

Dependencies

At least one MCPM card must be configured in the system if the Measurements Platform feature is turned on.

No other rept-stat-xxx commands can be in progress when this command is issued.

The Integrated Measurements or Measurements Platform feature must be turned on before this command can be entered.

The platformenable=on or oamhcmeas=on parameter must be specified (see the chg-measopts command) before this command can be entered.

This command cannot be entered when CAT2 IPSM to OAM syncing is in progress.

Notes

The card status is independent of the IP Network Link status (Port A). The card can be IS-NR even if the network link has failed.

The version of the GPL is shown in the command output if the card is in the IS-NR or IS-ANR state. The rept-stat-card command does not show the GPL version if the card is IS-ANR.

Output

Note:

The E5-MCPM-B card is an MCPM card. The Type field displays MCPM.

Output example with an MCPM card isolated:

rept-stat-meas

                          PST           SST        AST
    MEAS SS               IS-ANR        Active     -----
        ALARM STATUS =    *  0516 Degraded Mode - 1 card failed
                        
    CARD   VERSION         TYPE    PST           SST        AST
    1107 P 134-000-000     MCPM    IS-NR         Active     -----
       IP Link A                   IS-NR         Active     -----
    1109   -----------     MCPM    OOS-MT        Isolated   -----
       IP Link A                   OOS-MT        Unavail    -----

    CARD 1107 ALARM STATUS = No Alarms
    CARD 1109 ALARM STATUS = Card is isolated from the system
    Command Completed. 
;

Output example when the Integrated Measurements collection function is turned on:

rept-stat-meas

                          PST           SST        AST
    MEAS SS               IS-NR         Active     -----
        ALARM STATUS =   No Alarms

    CARD   VERSION      TYPE      GPL        PST            SST        AST
    1113 P 132-049-000  E5MCAP    OAMHC      IS-NR          Active     -----
       IP Link A                             IS-NR          Active     -----
    1115   132-049-000  E5MCAP    OAMHC      IS-NR          Active     -----
       IP Link A                             OOS-MT         Unavail    -----
    
    CARD 1113 ALARM STATUS = No Alarms
    CARD 1115 ALARM STATUS = No Alarms
    
    Command Completed. 
;

Output example with both MCPM cards IS-NR:

rept-stat-meas

    tekelec 11-03-15 20:34:15 EST  EAGLE5 44.0.0
                          PST           SST        AST
    MEAS SS               IS-NR         Active     -----
        ALARM STATUS =   No Alarms

    CARD   VERSION         TYPE    PST           SST        AST
    1106   134-000-000     MCPM    IS-NR         Active     -----
       IP Link A                   IS-NR         Active     -----
    1108   134-000-000     MCPM    IS-NR         Active     -----
       IP Link A                   IS-NR         Active     -----

    CARD 1106 ALARM STATUS = No Alarms
    CARD 1108 ALARM STATUS = No Alarms

    Command Completed. 
;

Legend

  • VERSION—Version number of the GPL running on the specified card. The version is shown if the card is in the IS-NR or IS-ANR state.
  • TYPE—Type of card running the Measurements Subsystem application
  • PST—Primary state of the Measurements Subsystem or card. See Possible Values for PST/SST/AST for more information.
  • SST—Secondary state of the Measurements Subsystem or card. See Possible Values for PST/SST/AST for more information.
  • AST—Associated state of the Measurements Subsystem or card. See Possible Values for PST/SST/AST for more information.
  • MEAS SS—Measurements Subsystem application running on the card
  • ALARM STATUS—List of trouble text alarm messages that have been generated for the card and the applications running on the card
  • CARD—Location of the card. The card with the letter “P” to the right of its card location is the primary card. The primary card transfers scheduled measurements report files to the primary FTP server. When the primary state (PST) of the card is IS-NR, the secondary state (SST) indicates whether the card is active or standby, and the value of the associated state (AST) remains "-----".
  • CARD XXXX ALARM STATUS—List of trouble text alarm messages that have been generated for the card

Related Topics