Move the Library Rack

Power off the library and lock the robot before moving the rack to prevent equipment damage.

  1. Power the library off (see Power Off the Library).
  2. Secure the robot (see Lock the Robot).
  3. If the floor is uneven, remove all magazines from library as tape cartridges can shift and obstruct library robotics when the library is restarted.
    1. Unlock all magazines using the remote interface or local operator panel. Press the Select All option on the Unlock Magazines dialog.
    2. Remove all magazines.
  4. Set the rack PDU circuit breakers to OFF and disconnect the PDU power cord(s) from the main circuit.
  5. Label and disconnect any host connection or LAN cables.
  6. Raise any leveling pads until the casters are supporting the rack. Release any rack anti-tip device(s), and remove any wheel chocks.
  7. Move the library to its new location. Reset the leveling pads.
  8. Reinstall the magazines.
  9. Reconnect power, host-connections, and local area network (LAN) cables.
  10. Unlock the robot (see Unlock the Robot).
  11. Power the library on (see Power On the Library).