Sun StorEdge
S1 Array Installation and Maintenance Manual
816-0080-12
|
Contents |
1. Sun StorEdge S1 Array Overview
Sun StorEdge S1 Array Overview
Optional Rackmounting Kit for Four-Post Racks
Components at the Front of the Array

To Remove the Nameplate From the Bezel

To Insert the Nameplate Into the Bezel
Components at the Back of the Array
System Power and System Summary Fault LEDs
Autotermination Indication LEDs
Sun StorEdge S1 Array Software Considerations
2. Preparing for Installation and Assembling the Cables
Determining the Number of Units to Install
Assembling the DC Input Power Cable (for DC Power Supplies)
Overview of Connecting to the DC Power Connector On the Array

To Assemble the DC Input Power Cable

To Remove a Wire from the DC Connector (if needed)

To Connect the Strain Relief Housing With the DC Connector
3. Installing the Sun StorEdge S1 Array
Mounting the Array in a Rack or Cabinet
Rack and Cabinet Installation Precautions

To Mount the Array Into a Four-Post Rack or Cabinet

To Mount the Array Into a Two-Post Rack
Setting the SCSI IDs for the Drives
Example: Single-Ended SCSI Configuration
Example: LVD SCSI Configuration
Example: Mixed Single-Ended and LVD SCSI Configuration

To Determine the Drive Bay's SCSI ID Sequence and Base ID

To Set the SCSI IDs for the Drives
LVD SCSI Example: Cabling Four Arrays in a Daisy Chain

To Cable Four Arrays in a Daisy Chain
Connecting and Disconnecting Power Cables

To Connect the DC Power Cables

To Disconnect the DC Power Cable from the DC Connector
Isolating the Chassis Ground Connection (DC Version Only)

To Isolate the Chassis Ground Connection
4. Adding, Removing, and Replacing Drives
Removing the Front Bezel to Access the Disk Drives

To Create a New Solaris Device Entry

To Configure a File System for a New Disk Drive
Removing and Replacing a Disk Drive

To Check the Binary SCSI ID LED Display
System Power and System Summary Fault LEDs
Checking Autotermination Indication LEDs
Cleaning the Sun StorEdge S1 Array Screens

To Clean the Front Bezel Screen

To Reattach the Bezel's Tethers to the Array
Removing and Replacing an Array
A. System Specifications and Site Requirements
Overcurrent Protection Requirements
Disconnecting the Power for Servicing
Overcurrent Protection Requirements
DC Supply and Ground Conductor Requirements
LVD SCSI Port Pin Descriptions
B. Declaration of Conformity, Regulatory Compliance, and Safety Statements
Copyright © 2003, Sun Microsystems, Inc. All rights reserved.