JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun SPARC Enterprise T5440 Server Topic Set
search filter icon
search icon

Document Information

Using This Documentation

Related Documentation

Documentation, Support, and Training

Site Planning

SPARC Enterprise T5440 Site Planning Guide

Physical Specifications

Minimum Clearance for Service Access

Environmental Specifications

Power Source Requirements

Acoustic Noise Emissions

Agency Compliance Specifications

Operating Environment Requirements

Installation and Setup

Preparing for Installation

About the SPARC Enterprise T5440 Server

Tools and Equipment Needed

Installation Overview

Cabling Notes

About the Slide Rail Assembly

About the Cable Management Arm

Rack Compatibility Requirements

Safety Precautions

ESD Precautions

Installing the SPARC Enterprise T5440 Server

Installing the Rack Slide Assembly

Installing the Server Into the Cabinet

Installing the Cable Management Arm (CMA)

Connecting the Server Cables

Managing Cables With the CMA

Powering On the System

Powering On the System for the First Time

Enabling the Service Processor Network Management Port

Logging Into the Service Processor

Using the Service Processor for Common Operations

Booting the Solaris Operating System

Updating the Firmware

Updating Service Processor and Server Firmware

Updating the Firmware

Selecting a Boot Device

Select a Boot Device

Administration

Basic Administrative Tasks

Initial System Setup

Communicating With the System

Performing Common Tasks

Manage Disk Volumes

Hardware RAID Support

Creating RAID Volumes

Removing Hardware RAID Volumes

Manage the System

Searching for Faults

Bypassing Minor Faults

Clearing Faults

Managing Devices

Use Logical Domains Software

Understanding Logical Domains Software

Operating the Solaris OS With Logical Domains

ALOM-to-ILOM Command Reference

ILOM and ALOM CMT Command Comparison Tables

Remote Management

Understanding ILOM for the Sun SPARC Enterprise T5440 Server

ILOM Overview

Platform-Specific ILOM Features

ILOM Features Not Supported

Managing the Host

Resetting the Host

Managing Host Boot Mode

Viewing and Configuring Host Control Information

Managing System User Interactions

Managing the Service Processor

Storing Customer Information

Display Console History (CLI)

Change Console Escape Characters (CLI)

Changing Configuration Policy Settings

Managing Network Access

Managing Devices

Managing Virtual Keyswitch Settings

IPMI Sensor Reference

Sensors on Sun SPARC Enterprise T5440 Server

Indicators on the Sun SPARC Enterprise T5440 Server Server

ALOM CMT Compatibility Shell

Limits to Backward Compatibility

Create an ALOM CMT Compatibility Shell

ILOM and ALOM CMT Command Comparison

ALOM CMT Variables

ALOM CMT Variable Comparison

Event Messages Available Through the ALOM Compatibility Shell

Event Message Overview

Event Severity Levels

Service Processor Usage Event Messages

Environmental Monitoring Event Messages

Host Monitoring Event Messages

SCC Backup and Restore

Information Stored on The SCC

Service

Identifying Server Components

Infrastructure Boards and Cables

Front Panel Diagram

Front Panel LEDs

Rear Panel Diagram

Rear Panel LEDs

Ethernet Port LEDs

Managing Faults

Understanding Fault Handling Options

Connecting to the Service Processor

Displaying FRU Information With Oracle ILOM

Controlling How POST Runs

Detecting Faults

Clearing Faults

Disabling Faulty Components

Oracle ILOM-to-ALOM CMT Command Reference

Preparing to Service the System

Safety Information

Required Tools

Obtain the Chassis Serial Number

Obtain the Chassis Serial Number Remotely

Powering Off the System

Extending the Server to the Maintenance Position

Remove the Server From the Rack

Perform Electrostatic Discharge – Antistatic Prevention Measures

Remove the Top Cover

Servicing Customer-Replaceable Units

Hot-Pluggable and Hot‐Swappable Devices

Servicing Hard Drives

Servicing Fan Trays

Servicing Power Supplies

Servicing PCIe Cards

Servicing CMP/Memory Modules

Servicing FB-DIMMs

Servicing Field-Replaceable Units

Servicing the Front Bezel

Servicing the DVD-ROM Drive

Servicing the Service Processor

Servicing the IDPROM

Servicing the Battery

Servicing the Power Distribution Board

Servicing the Fan Tray Carriage

Servicing the Hard Drive Backplane

Servicing the Motherboard

Servicing the Flex Cable Assembly

Servicing the Front Control Panel

Servicing the Front I/O Board

Returning the Server to Operation

Install the Top Cover

Install the Server Into the Rack

Slide the Server Into the Rack

Connect the Power Cords to the Server

Power On the Server

Performing Node Reconfiguration

I/O Connections to CMP/Memory Modules

Recovering From a Failed CMP/Memory Module

System Bus Topology

I/O Fabric in 2P Configuration

I/O Fabric in 4P Configuration

Identifying Connector Pinouts

Serial Management Port Connector Pinouts

Network Management Port Connector Pinouts

Serial Port Connector Pinouts

USB Connector Pinouts

Gigabit Ethernet Connector Pinouts

Server Components

Customer-Replaceable Units

Field-Replaceable Units

Index

Environmental Monitoring Event Messages

The following table displays environmental monitoring event messages from the service processor (system contoller).

Table 31 Environmental Monitoring Event Messages

Severity
Message
Description
Critical
SP detected fault at time time. Chassis cover removed.
ALOM compatibility shell sends this message if the chassis cover has been removed. The platform hardware turns managed system power off immediately as a precautionary measure. The event message System poweron is disabled should accompany this message to prevent the use of the poweron command while the chassis cover is removed.
Major
System poweron is disabled.
ALOM compatibility shell sends this message when the SC refuses to power on the system, either through the user poweron command or by the front panel power button. The SC disables power on because of an accompanying event, such as the event indicated by the message Chassis cover removed. Other possibilities include a device failure or insufficient fan cooling.
Major
System poweron is enabled.
ALOM compatibility shell sends this message after the condition that caused power on to be disabled (indicated by the preceding System poweron is disabled message) has been rectified. For example, by replacing the chassis cover or installing sufficient fans to cool the system.
Major
SP detected fault at time time “fault_type 'fault' at location asserted"
ALOM compatibility shell sends this message when a failure or a fault is detected. A fault is a lower priority condition that indicates the system is operating in a degraded mode. fault_type is the type of failure that has occured, such as temperature, voltage, current, or power supply. The location is the location and name of the device that has the error condition. The location and name of the device match the output of the ALOM compatibility shell showenvironment command.

This fault event message appears in the output of the ALOM compatibility shell showfaults command.

Minor
SP detected fault cleared at time time current fault at device asserted.
ALOM compatibility shell sends this message to indicate that a prior fault or failure has recovered or been repaired. The fields (time and device) are the same as the prior fault or failure event.
Major
Device_type at location has exceeded low warning threshold.

ALOM compatibility shell sends these messages when analog measurement sensors have exceeded the specified threshold.

The threshold that was exceeded is included in the message.

Device_type is the type of device that has failed, such as VOLTAGE_SENSOR or TEMP_SENSOR. The location is the location and name of the device that has the error condition. The location and name of the device match the output of the ALOM compatibility shell showenvironment command.

For TEMP_SENSOR events, this message could indicate a problem outside of the server, such as the temperature in the room or blocked airflow in or out of the server. For VOLTAGE_SENSOR events, this message indicates a problem with the platform hardware or possibly with add-on cards installed.

These fault event messages appear in the output of the ALOM compatibility shell showfaults command.

Critical
Device_type at location has exceeded low critical shutdown hreshold.
Critical
Device_type at location has exceeded low nonrecoverable shutdown threshold
Major
Device_type at location has exceeded high warning threshold
Critical
Device_type at location has exceeded high soft shutdown threshold
Critical
Device_type at location has exceeded high hard shutdown threshold
Minor
Device_type at location is within normal range.
ALOM compatibility shell sends this message when an analog measurement sensor no longer exceeds any warning or failure thresholds. This message is sent only if the sensor reading recovers sufficiently within the boundaries of the failure parameters. The message might not match the current output of the ALOM compatibility shell showenvironment command.
Critical
Critical temperature value: host should be shut down
ALOM compatibility shell sends this message to indicate that the SC has started a shutdown because there are not enough working fans necessary to keep the system cooled. The number of fans necessary to maintain system cooling depends on the platform. See your platform documentation for more information.
Critical
Host system failed to power off.
ALOM compatibility shell sends this message if the SC is unable to power off the system. This message indicates a problem with either the platform hardware or the SC hardware. The system should be manually unplugged to prevent damage to the platform hardware.This fault event message appears in the output of the ALOM compatibility shell showfaults command.
Major

Minor

FRU_type at location has been removed.

FRU_type at location has been inserted.

ALOM compatibility shell sends these messages to indicate that a FRU has been removed or inserted. The field FRU_type indicates the type of FRU, such as SYS_FAN,PSU, or HDD. The field location indicates the location and name of the FRU, as shown in the output of the showenvironment command.
Major
Input power unavailable for PSU at location.
ALOM compatibility shell sends this message to indicate that a power supply is not receiving input power. This message normally indicates that the power supply is not plugged in to AC power. If the power cords are plugged in to an outlet that is provided power, this message indicates a problem with the power supply itself.This fault event message appears in the output of the ALOM compatibility shell showfaults command.