Sun Fire V60x and Sun Fire V65x Server User Guide
817-2023-11
Contents |
1. Introducing the Sun Fire V60x and Sun Fire V65x Servers
1.1 Overview of the Sun Fire V60x and Sun Fire V65x Servers
1.1.3.2 Network Infrastructure Services
1.3 Front Panel and Peripheral Bays
1.4 Front Panel Controls and Indicators
1.5 Rear Panel Ports and Features
1.9 Optional RJ-45 to DB9 Serial Adapter Kit
2. Installing the Server in a Rack
2.1 Decide Where to Configure the Sun Fire V60x and Sun Fire V65x Servers
2.4 Installing the Server Using the Bracket Kit
2.4.3 Mounting in a Four-Post Rack System
2.4.3.1 Remove the Chassis Handles
2.4.3.2 Attach Brackets to Chassis
2.4.3.3 Attach Chassis Disks to Chassis
2.4.3.4 Attach Brackets to Rear Posts
2.4.3.5 Install Chassis in Rack
2.4.3.6 Install Chassis Handles
2.4.4 Mid-Mounting in a Two-Post Rack System
2.4.4.1 Attach Brackets to Chassis
2.4.4.2 Attach L Brackets to Center Posts
2.4.4.3 Install Chassis in Rack
2.4.5 Front-Mount-Only in a Two-Post Rack System
2.4.5.1 Remove the Chassis Handles
2.4.5.2 Attach Brackets to Chassis
2.4.5.3 Attach L Brackets to Front Posts
2.4.5.4 Install Chassis in Rack
2.4.5.5 Install Chassis Handles
2.5 Installing the Server Using the Slide Rail Kit (Optional)
2.5.4 Attach Inside Rails to Chassis
2.5.5 Attach Rail Brackets to Posts
2.5.6 Attach a Rail Assembly to a Front Bracket
2.5.7 Attach a Rail Assembly to a Rear Bracket
2.5.8 Install the Chassis on the Rails
2.6.2.1 RJ-45 NIC 1 and NIC 2 Connectors
2.6.2.3 Rear Panel RJ-45 Serial COM2 Connector
2.6.2.5 PS/2 Keyboard/Mouse Connector
3.1 Front Panel LEDs and Pushbuttons
4. Powering Up and Configuring the Server
4.2 Setting the Serial COM2 Port Jumper
4.4.2 Using the Clear CMOS Jumper
4.5.1.1 BIOS Setup Utility <F2>
4.5.1.2 Service Partition <F4>
4.5.1.4 Choose Boot Device <ESC>
4.5.2.2 USB-Connected External CD-ROM Drives
4.5.2.3 Booting the Server When an External SCSI Hard Drive is Connected
4.5.2.4 PS/2 Mouse Misidentification
4.6 Loading the Operating System
4.7 Hyper-threadingTM CPU Feature
4.8 Configuring an External Serial Console
4.9 Using the Service Partition Menu
4.9.2.1 Run System Setup Utility
4.9.2.2 Using the SSU to Manage Logs, Records, Hardware, and Events
4.9.2.3 Run Platform Confidence Test (PCT)
4.9.2.4 Run Baseboard Management Controller (BMC) Firmware Update
4.9.2.5 Run HSC Firmware Update
4.9.2.6 Run Field Replaceable Unit/Sensor Data Record (FRU/SDR) Update3
4.9.2.7 Run BIOS Update (reboot required)
4.9.2.8 Reboot to Service Partition
4.10 Using the Sun Diagnostics CD
4.10.4 Restoring the Service Partition
4.11 Updating the Server Configuration
4.11.1 Using the Diskette to Update the Server BIOS
4.12 Restarting and Shutting Down
4.12.1.1 Software Shutdown Commands for Linux
4.12.1.2 Software Shutdown Commands for Solaris
5.2 Determining a Faulty Component
5.3 Safety Guidelines (Before You Remove the Cover)
5.4 Removing and Replacing the Cover
5.5 Customer Replaceable Unit (CRU) Procedures
5.5.2 Floppy/DVD/CD-ROM Combo Module
5.5.3.1 Sun Fire V60x Server DIMM Replacement
5.5.3.2 Sun Fire V65x Server DIMM Replacement
5.5.3.3 Installing the DIMM Fan (Sun Fire V65x Server Only)
5.5.4 Replacing a Server CPU and Heatsink
5.5.4.2 Sun Fire V60x Server Heatsink and Processor Removal
5.5.4.3 Sun Fire V60x Server Heatsink and Processor Replacement
5.5.4.4 Sun Fire V65x Server Heatsink and Processor Removal
5.5.4.5 Sun Fire V65x Server Heatsink and Processor Replacement
5.5.5 Sun Fire V60x and Sun Fire V65x Servers New CPU and Heatsink Installation
5.5.6.1 Sun Fire V60x Server Power Supply
5.5.6.2 Sun Fire V65x Server Power Supply
5.5.8.1 Sun Fire V60x Server Air Baffle Removal
5.5.8.2 Sun Fire V60x Server Air Baffle Installation
5.5.8.3 Sun Fire V65x Server Air Baffle Removal
5.5.8.4 Sun Fire V65x Server Air Baffle Installation
5.5.9.1 Sun Fire V60x Server Fan Module Removal
5.5.9.2 Sun Fire V60x Server Fan Module Replacement
5.5.9.3 Sun Fire V65x Server Fan Module Removal
5.5.9.4 Sun Fire V65x Server Fan Module Replacement
5.5.12 Keyboard/Mouse "Y" Adapter
5.5.13 Emergency Management Port Cable
5.5.13.1 Installing the DSR Peripherals Cable
5.5.13.2 Installing the DCD Modem Cable
5.6 Field Replaceable Unit (FRU) Procedures
5.6.1.1 Sun Fire V60x Server Main Board Replacement
5.6.1.2 Sun Fire V65x Server Main Board Replacement
5.6.2.1 Sun Fire V60x Server Cable Kit Removal
5.6.2.2 Sun Fire V60x Server Cable Kit Installation
5.6.2.3 Sun Fire V65x Server Cable Kit Removal
5.6.2.4 Sun Fire V65x Server Cable Kit Installation
5.6.3.1 Sun Fire V60x and Sun Fire V65x Servers System FRU Installation
6.1.4.1 Platform Confidence Test (PCT)
6.1.4.2 System Setup Utility (SSU)
6.2.1 Front-Panel System Status LED
6.2.2 Rear Panel Power Supply Status LED
6.3 Server Main Board Fault LEDs
6.5.3 BIOS Recovery Beep Codes
6.6 Contacting Technical Support
7.1 Single or Dual Intel® Xeon Processors
7.9 Server Management Features
A.1.2 RAID Installation Procedure
A.2.2.1 RAID 0 (Data Striping)
A.2.2.2 RAID 1 (Disk Mirroring/Disk Duplexing)
A.2.2.3 RAID 4 (Data Striping with a Dedicated Parity Drive)
A.2.2.4 RAID 5 (Data Striping with Striped Parity)
A.2.2.5 RAID 10 (Combination of RAID 1 and RAID 0)
A.2.2.6 Levels of Drive Hierarchy Within the RAID Firmware
A.2.2.7 Transparency of Host Drives
A.2.2.8 Using CD-ROMs, DATs, and Tape Drives
A.3 Preparing for Installation
A.5.1 SCSI Hard Disk Drive Support
A.5.2 Non-SCSI Hard Disk Drive Support
A.7 RAID Controller Drive Limitations
Copyright © 2003, Sun Microsystems, Inc. All rights reserved.