Preparing for the Installation
Confirming Server Specifications
Optional Component Installation
Stabilize the Rack for Installation
Verify Operation of Slide Rails and CMA
Rear Panel Connectors and Ports
Connect the Ethernet Network Cables
Connect the Network Module Cables
Powering On the Server for the First Time
Connect a Terminal or Emulator to the SER MGT Port
Power On the System for the First Time
Oracle Solaris OS Configuration Parameters
Assign a Static IP Address to the SP
Understanding System Administration Resources
Platform-Specific Oracle ILOM Features
Oracle VM Server for SPARC Overview
Hardware Management Pack Overview
Source for Downloading Hardware Management Pack Software
Hardware Management Pack Documentation
Display the Oracle ILOM -> Prompt
Reset the Server From the Oracle Solaris OS
Reset the Server From Oracle ILOM
Reset the SP to Default Values
Important Hardware RAID Guidelines
Disk Zones for SPARC T3-1 Servers With Sixteen-Disk Backplanes
Displaying Disk Zone Information
Enabling and Disabling Disk Zoning In the Field
Prepare to Use the FCode Utility
Hot Spare Drives in RAID Volumes (LSI)
Determining If a Drive Has Failed
RAID Drive Replacement Strategies
Changing Server Identification Information
Change Customer FRUdata Information
Change System Identifier Information
Restore Host Power State at Restart
Specify Host Power State at Restart
Disable or Re-Enable Power-On Delay
Specify Parallel Boot of the SP and Host
Configure Host Behavior With the Keyswitch State
Disable or Re-Enable Network Access to the SP
Display the DHCP Server IP Address
Using an In-band Connection to the SP
Configure the Host Boot Mode of Oracle VM Server for SPARC
Change the Host Boot Mode Behavior at Reset
Manage the Host Boot Mode Script
Display Host Boot Mode Expiration Date
Override OpenBoot PROM Settings to Reset the Server
Configuring Server Behavior at Restart
Specify Behavior When the Host Resets
Specify Behavior When the Host Stops Running
Specify Behavior at Boot Timeout
Specify Behavior if Restart Fails
Specify Maximum Restart Attempts
Enabling Automatic System Recovery
Identifying WWN-Designated SAS2 Devices
probe-scsi-all Output Example (SPARC T3-1, Eight-Disk Backplane)
probe-scsi-all Output Example (SPARC T3-1, Sixteen-Disk Backplane)
probe-scsi-all Output Example (SPARC T3-4)
Identify a Disk Slot Using probe-scsi-all (OBP)
Identify a Disk Slot Using prtconf (Oracle Solaris, Onboard Controllers)
Identify a Disk Slot Using prtconf (Oracle Solaris, Single Initiator)
WWN Syntax in an OS Installation on a Specific Device
WWN Syntax in an OS Installation on a RAID Volume
Infrastructure Boards in the Server
Interpreting Log Files and System Messages
Using the Oracle Solaris Predictive Self-Healing Feature
Managing Components With Automatic System Recovery Commands
Checking if SunVTS Software Is Installed
Find the Chassis Serial Number
Understanding Component Replacement Categories
Removing Power From the System
Positioning the System for Servicing
Attaching Devices to the Server
Locate a Faulty Hard Disk Drive
Remove a Hard Disk Drive Filler Panel
Install a Hard Disk Drive Filler Panel
Verify Hard Disk Drive Functionality
Verify Fan Module Functionality
Verify Power Supply Functionality
Servicing Memory Risers and DIMMs
Locate a Faulty DIMM (DIMM Fault Remind Button)
Locate a Faulty DIMM (show faulty Command)
Increase Server Memory With Additional DIMMs
Remove a Memory Riser Filler Panel
Install a Memory Riser Filler Panel
DIMM Configuration Error Messages
Remove a DVD Drive or Filler Panel
Install a DVD Drive or Filler Panel
Servicing the System Lithium Battery
Servicing Expansion (PCIe) Cards
Remove a PCIe Card Filler Panel
Cable an Internal SAS HBA PCIe Card
Install a PCIe Card Filler Panel
Verify Fan Board Functionality
Verify Motherboard Functionality
Servicing the Service Processor
Service Processor Firmware and Configuration
Verify Service Processor Functionality
Servicing the Hard Disk Drive Backplane
Remove the Hard Disk Drive Backplane
Install the Hard Disk Drive Backplane
Verify Hard Disk Drive Backplane Functionality
Servicing the Power Supply Backplane
Remove the Power Supply Backplane
Install the Power Supply Backplane
Verify Power Supply Backplane Functionality
Returning the Server to Operation
Return the Server to the Normal Rack Position
Use this procedure to install the server chassis, with mounting brackets, into the slide rail assemblies that are mounted to the rack.
Caution - This procedure requires a minimum of two people because of the weight of the server. Attempting this procedure alone could result in equipment damage or personal injury. |
Caution - Always load equipment into a rack from the bottom up so that the rack will not become top-heavy and tip over. Extend your rack’s anti-tip bar or anti-tilt legs to prevent the rack from tipping during equipment installation. See Stabilize the Rack for Installation for more information. |
Caution - When inserting the server into the slide rail, ensure that both the top and bottom mounting lips of the mounting brackets are inserted into the slide rail. The server should slide forward and backward easily if correctly installed. If the unit does not slide easily, ensure that each mounting lip is inserted properly. If the mounting brackets are not inserted properly, the unit might fall when it is removed from the rack. |
Continue pushing until the slide rail locks (on the front of the mounting brackets) engage the slide rail assemblies. You will hear an audible click.
Caution - Verify that the server is securely mounted in the rack and that the slide rail locks are engaged with the mounting brackets before continuing. |