Sun Logo


Sun StorEdgetrademark S1 Array Installation and Maintenance Manual

816-0080-12



Contents

1. Sun StorEdge S1 Array Overview

Sun StorEdge S1 Array Overview

Features

Ship Kit Contents

Supported Cables

Optional Rackmounting Kit for Four-Post Racks

Components at the Front of the Array

procedure iconsmall spaceTo Remove the Nameplate From the Bezel

procedure iconsmall spaceTo Insert the Nameplate Into the Bezel

Removing the Front Bezel

procedure iconsmall spaceTo Remove the Bezel

Components at the Back of the Array

Power Switch

SCSI ID Switch

Back Panel LEDs

System Power and System Summary Fault LEDs

Autotermination Indication LEDs

For More Information

Internal Components

Power Supply

AC Power Supply Option

DC Power Supply Option

Cooling System

Disk Drives

Foam Fillers

Sun StorEdge S1 Array Software Considerations

2. Preparing for Installation and Assembling the Cables

Installation Overview

Preparing for Installation

Hardware Requirements

Tools and Equipment Needed

Determining the Number of Units to Install

Determining Cable Length

Assembling the DC Input Power Cable (for DC Power Supplies)

Required Connection Materials

Overview of Connecting to the DC Power Connector On the Array

procedure iconsmall spaceTo Assemble the DC Input Power Cable

procedure iconsmall spaceTo Remove a Wire from the DC Connector (if needed)

procedure iconsmall spaceTo Connect the Strain Relief Housing With the DC Connector

3. Installing the Sun StorEdge S1 Array

Mounting the Array in a Rack or Cabinet

Rack and Cabinet Installation Precautions

procedure iconsmall spaceTo Mount the Array Into a Four-Post Rack or Cabinet

procedure iconsmall spaceTo Mount the Array Into a Two-Post Rack

Setting the SCSI IDs for the Drives

Example: Single-Ended SCSI Configuration

Example: LVD SCSI Configuration

Example: Mixed Single-Ended and LVD SCSI Configuration

procedure iconsmall spaceTo Determine the Drive Bay's SCSI ID Sequence and Base ID

procedure iconsmall spaceTo Set the SCSI IDs for the Drives

Connecting the SCSI Cables

procedure iconsmall spaceTo Prepare the Host System

procedure iconsmall spaceTo Connect the SCSI Cables

LVD SCSI Example: Cabling Four Arrays in a Daisy Chain

procedure iconsmall spaceTo Cable Four Arrays in a Daisy Chain

Connecting and Disconnecting Power Cables

procedure iconsmall spaceTo Connect the AC Power Cable

procedure iconsmall spaceTo Connect the DC Power Cables

procedure iconsmall spaceTo Disconnect the DC Power Cable from the DC Connector

Isolating the Chassis Ground Connection (DC Version Only)

procedure iconsmall spaceTo Isolate the Chassis Ground Connection

Powering On the Array

procedure iconsmall spaceTo Power On the Array

procedure iconsmall spaceTo Power On the Host System

Hot-Swapping a SCSI Device

procedure iconsmall spaceTo Hot-Swap a SCSI Device

4. Adding, Removing, and Replacing Drives

Removing the Front Bezel to Access the Disk Drives

Adding a Disk Drive

procedure iconsmall spaceTo Add a Disk Drive

Configuring the Software

procedure iconsmall spaceTo Create a New Solaris Device Entry

procedure iconsmall spaceTo Configure a File System for a New Disk Drive

Removing and Replacing a Disk Drive

procedure iconsmall spaceTo Remove a Disk Drive

procedure iconsmall spaceTo Replace a Disk Drive

5. Maintenance Tasks

Powering Off the Array

procedure iconsmall spaceTo Power Off the Array

Troubleshooting

Checking Front Panel LEDs

procedure iconsmall spaceTo Check the Binary SCSI ID LED Display

Checking Back Panel LEDs

System Power and System Summary Fault LEDs

Checking Autotermination Indication LEDs

Cleaning the Sun StorEdge S1 Array Screens

procedure iconsmall spaceTo Clean the Front Bezel Screen

procedure iconsmall spaceTo Reattach the Bezel's Tethers to the Array

procedure iconsmall spaceTo Clean the Back Fan Screens

Removing and Replacing an Array

A. System Specifications and Site Requirements

Physical Specifications

Electrical Site Requirements

AC Power Requirements

Overcurrent Protection Requirements

Disconnecting the Power for Servicing

DC Source Power Requirements

Overcurrent Protection Requirements

DC Supply and Ground Conductor Requirements

Environmental Specifications

Acoustic Emissions

LVD SCSI Port Pin Descriptions

B. Declaration of Conformity, Regulatory Compliance, and Safety Statements

Declaration of Conformity

Regulatory Compliance Statements

Safety Agency Compliance Statements