About This Documentation (PDF and HTML)
Overview of the Sun Blade Storage Module M2
Installing the Storage Module Into the Chassis
Assigning and Managing Storage
Overview of the Sun Blade Storage Module M2 Product Notes
Supported Firmware, Hardware and Software
Solaris Operating System Issues
Performing Maintenance and Hot Plug Actions
Importing Existing Virtual Drives to a Replacement REM
Storage Module Sensors and Indicators
Displaying Sensor and Indicator Information Using the CMM ILOM Web Interface
Introduction to the Sun Blade Storage Module M2
Maintaining the Sun Blade Storage Module M2
All sensors for the storage module are located in the /CH/BLx namespace. Where BLx refers to the blade slot in the chassis in which the storage module is installed.
To display the sensors using the CMM ILOM CLI, separate the fields into targets and navigate using the cd and show commands. For example, to show all components in the storage module installed in chassis blade slot 7, enter the following command at the CMM ILOM CLI prompt:
–> show /CH/BL7
The output might look like:
/CH/BL7
Targets:
MB
HDD0
HDD1
HDD2
HDD3
HDD4
HDD5
HDD6
HDD7
PRSNT
STATE
ERR
OK
SERVICE
OK2RM
LOCATE
Properties:
type = Blade
ipmi_name = BL7
fru_name = SUN BLADE STORAGE MODULE M2
fru_part_number = 511-1365-02
fru_serial_number = 00000000
fru_extra_1 = SAS0 5.3.5.0, SAS1 5.3.5.0
fault_state = OK
load_uri = (none)
clear_fault_action = (none)
power_state = On
Commands:
cd
load
reset
set
show
The following commands can be used to navigate to supported storage module targets. Each target supports its own list of allowable commands—not all commands in the table below work for all targets.
|
![]() | Caution - The reset command does not check for host activity. You should only use these commands if you are sure that the device is not in use. |