JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Blade Storage Module M2 Product Documentation
search filter icon
search icon

Document Information

Preface

Product Information Web Site

Related Books

About This Documentation (PDF and HTML)

Documentation Comments

Change History

Hardware Installation

Overview of the Sun Blade Storage Module M2

System Requirements

Installing the Storage Module Into the Chassis

Storage Module Indicators

Assigning and Managing Storage

Product Notes

Overview of the Sun Blade Storage Module M2 Product Notes

Supported Firmware, Hardware and Software

Hardware Issues

Solaris Operating System Issues

Linux Operating System Issues

Administration

Assigning Storage to Hosts

Managing Storage

Performing Maintenance and Hot Plug Actions

Importing Existing Virtual Drives to a Replacement REM

Storage Module Sensors and Indicators

Troubleshooting

Viewing the CMM ILOM Event Log

Sun Blade Zone Manager Issues

Sun Blade Zone Manager Not Ready

Missing SAS-2 Components Error

Server Module Not SAS-2 Capable Error

Newly Inserted NEM is Not Discovered

Storage Module Issues

Storage Module Becomes Inaccessible at Host and ILOM /CH/BLx/fault_state is "Faulted"

Storage Module Becomes Inaccessible at Host and ILOM /CH/BLx/STATE is "Degraded"

Storage Module Fault LED is On

The Storage Module Powers Off

NEM Issues

SAS Path Disappears and ILOM /CH/NEMx/fault_state is "Faulted"

NEM Fault LED is On

NEM STATE (/CH/NEMx/STATE) is Not "Running"

NEM /CH/NEMx/OK Indicator is in Standby Blink

Service

Introduction to the Sun Blade Storage Module M2

Maintaining the Sun Blade Storage Module M2

Diagnosing Storage Module Faults

Specifications

Index

Server Module Not SAS–2 Capable Error

If you are trying to assign storage module resources to a server module that does not have a SAS-2 REM, you will see a “Not SAS-2 Capable” error listed in the Sun Blade Zone Manager.

What to look for:

The following table provides examples of how the web interface and CLI might look like when you have servers that are not SAS-2 capable.

CMM ILOM
If Server Blade is Not SAS-2 Capable
Web interface
In Sun Blade Zone Manager configuration window.image:Graphic showing server module that is non-SAS-2 capable.
CLI
-> show –level all

/STORAGE/sas_zoning
    Targets:
        BL1
        BL2
        BL3     <-- Note: only SAS-2 capable blades
        BL7         (servers, storage modules) are shown.
        BL8
        NEM0
        NEM1

    Properties:
        zone_management_state = enabled
        reset_password_action = (Cannot show property)
        reset_access_action = (Cannot show property)
 

Actions to perform: