JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Blade Storage Module M2 Product Documentation
search filter icon
search icon

Document Information

Preface

Product Information Web Site

Related Books

About This Documentation (PDF and HTML)

Documentation Comments

Change History

Hardware Installation

Overview of the Sun Blade Storage Module M2

System Requirements

Installing the Storage Module Into the Chassis

Storage Module Indicators

Assigning and Managing Storage

Product Notes

Overview of the Sun Blade Storage Module M2 Product Notes

Supported Firmware, Hardware and Software

Hardware Issues

Solaris Operating System Issues

Linux Operating System Issues

Administration

Assigning Storage to Hosts

Managing Storage

Performing Maintenance and Hot Plug Actions

Importing Existing Virtual Drives to a Replacement REM

Storage Module Sensors and Indicators

Troubleshooting

Viewing the CMM ILOM Event Log

Sun Blade Zone Manager Issues

Sun Blade Zone Manager Not Ready

Missing SAS-2 Components Error

Server Module Not SAS-2 Capable Error

Newly Inserted NEM is Not Discovered

Storage Module Issues

Storage Module Becomes Inaccessible at Host and ILOM /CH/BLx/fault_state is "Faulted"

Storage Module Becomes Inaccessible at Host and ILOM /CH/BLx/STATE is "Degraded"

Storage Module Fault LED is On

The Storage Module Powers Off

NEM Issues

SAS Path Disappears and ILOM /CH/NEMx/fault_state is "Faulted"

NEM Fault LED is On

NEM STATE (/CH/NEMx/STATE) is Not "Running"

NEM /CH/NEMx/OK Indicator is in Standby Blink

Service

Introduction to the Sun Blade Storage Module M2

Maintaining the Sun Blade Storage Module M2

Diagnosing Storage Module Faults

Specifications

Index

NEM STATE (/CH/NEMx/STATE) is Not “Running”

Under normal circumstances the STATE sensor of the NEM will report that the NEM is “Running.” If the NEM is in another state, you might see that one of the SAS paths to storage module resources is missing (two NEMs are required for a dual path connection to disks).

What to look for:

The following table provides examples of how the web interface and CLI might look like when the NEM is not in the “Running” state.

CMM ILOM
NEM State is On Line
Web interface
In CMM—>System Monitoring->Components.image:Graphic showing a NEM STATE as online.
CLI
-> show show /CH/NEM1/STATE

 /CH/NEM1/STATE
    Targets:

    Properties:
        type = Module
        ipmi_name = NEM1/STATE
        class = Discrete Sensor
--> value = On Line
        alarm_status = cleared

    Commands:
        cd
        show

Things to check:

Confirm that the prepare_to_remove_status is "Not Ready". The NEM should only be in the ready to remove state during a hot plug action. Do the following in the CMM ILOM CLI:

  1. Log into the CMM with administrator privileges.

  2. Enter the command:

    -> cd /CH/NEMx

    Where x is the slot number of the NEM.

  3. Check the prepare_to_remove_status by entering the command:

    -> ls

    Output might look like:

     /CH/NEM1
        Targets:
            MB
            SAS
            SP
            PRSNT
            STATE
            ERR
            OK
            SERVICE
            OK2RM
            LOCATE
    
        Properties:
            type = Network Express Module
            ipmi_name = NEM1
            system_identifier = SUNSP00212829EE4A
            fru_name = SUN BLADE 6000 VIRTUALIZED MULTI-FABRIC 10GE NEM M2
            fru_version = FW 3.0.10.16, SAS 5.3.5.0
            fru_part_number = 540-7961-02
            fru_extra_1 = FW 3.0.10.16, SAS 5.3.5.0
            fault_state = OK
            load_uri = (none)
            clear_fault_action = (none)
    --> prepare_to_remove_status = NotReady
            prepare_to_remove_action = (none)
            return_to_service_action = (none)
    
        Commands:
            cd
            load
            reset
            set
            show

Actions to perform:

If the prepare_to_remove_status is "Ready", the NEM is offline and in a state for hot plug removal. What you do depends on how it got into that state. Bring the NEM back to its “Running” state by doing one of the following: