Documentation, Support, and Training
Understanding Switch Specifications
Understanding InfiniBand Cabling
Understanding the Installation
Install the Switch in the Rack
Verifying the InfiniBand Fabric
Administrative Command Overview
Display Switch Environmental and Operational Data
Display Switch Firmware Versions
Locate a Switch Chip or Connector From the GUID
Display Switch Chip Boot Status
Display Switch Chip Port Status
Monitoring the InfiniBand Fabric
Controlling the InfiniBand Fabric
Understanding Service Procedures
The checkpower command performs a simple pass-fail test on the power supplies.
On the management controller, type:
# checkpower PSU 0 present status: OK PSU 1 present status: Alert #
If you see the words Alert or Not Present in the command output, perform the following steps for the affected power supply.
Remove the power cord from the affected power supply.
Remove the affected power supply from the switch chassis.
Wait one minute.
Reinstall the power supply.
Re-attach the power cord.
If the power supply’s Attention LED lights or the checkpower command still reports Alert or Not Present for the power supply, replace the power supply.
Switch Reference, checkpower command