checkvoltages Command

Verifies voltages.

Syntax

checkvoltages

Description

This hardware command displays the internal voltages for the main board. The left column displays the expected voltage, and the right column displays the measured voltage. The command also provides a summary of the voltage conditions.

Example

The following example shows how to check that voltages are at nominal values with the checkvoltages command.

# checkvoltages
Voltage ECB OK
Measured 3.3V Main = 3.28 V
Measured 3.3V Standby = 3.37 V
Measured 12V = 12.00 V
Measured 5V = 5.10 V
Measured VBAT = 3.08 V
Measured 1.8V = 1.77 V
Measured 1.2V Standby = 1.21 V
Measured 1.8V Standby = 1.80 V
Measured 2.5VA = 2.51 V
Measured 2.5VB = 2.51 V
Measured 1.2VA = 1.22 V
Measured 1.2VB = 1.21 V
Measured 1.2VC = 1.21 V
Measured 1.2VD = 1.22 V
Measured 1.2VE = 1.21 V
Measured 1.2VF = 1.21 V
All voltages OK
#