JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Storage F5100 Flash Array Topic Set
search filter icon
search icon

Document Information

Preface

Related Documentation

Documentation, Support, and Training

Documentation Feedback

Installation

Installing the System

Preparing for Installation

Rackmounting the System

Cabling the System

Power On

Managing the System

Power Off

Service

Sun Storage F5100 Flash Array Overview

Overview

Replaceable Components

Hot-Swappable Components

Obtaining the Chassis Serial Number

Diagnosing System Faults

Choosing a Method for Diagnosing Faults

Diagnosing Faults With Sun StorageTek Common Array Manager Software

Diagnosing Faults With LEDs and Indicators

Troubleshooting Components

Preparing to Service the System

Safety Information

Service Preparation Reference

Powering the System Off

Performing an Antistatic Discharge

Positioning the Chassis

Accessing Internal Components

Replacing System Components

Component Overview

Customer-Replaceable and Field-Replaceable Components

Replacing Flash Modules

Replacing a Fan Module

Replacing a Power Supply

Replacing an Energy Storage Module

Replacing Fan Boards

Replacing the Motherboard Assembly

Replacing a Power Distribution Board

Replacing the Connector Board Assembly

Replacing the Energy Storage Backplane

Returning the System to Service

Replace the Top Chassis Cover

Install the Chassis to Maintenance Position

Return the System to the Fully Installed Position

Install AC Power Cord Retention Clips

Power On the System

Index

Replaceable Components

Sun Storage F5100 Flash Array Replaceable Components  lists the after-factory options and replaceable components for Sun Storage F5100 Flash Array. The last column of the table indicates whether the items are customer-replaceable units (CRUs) or field-replaceable units (FRUs), which must be replaced by Sun Service.

Table 1 Sun Storage F5100 Flash Array Replaceable Components 

Component
Part Number (FRU/CRU)
CRU or FRU
Power Supply 720W (two per array)
F300-2137
CRU
Power cord retention clip (two per array)
F540-7861
CRU
Energy storage module (ESM) cap assembly
F541-3259
CRU
Fan module pair (three fan module pairs per array, six fans total)
F541-1984
CRU
Flash Modules (80 per array)
F371-4091
CRU
Motherboard-to-ESM cable
F560-2928
FRU
Motherboard-to-PDB cable
F530-3927
CRU
Bus bar
F541-2075
FRU
Connector Board with ribbon cable
F541-2183
FRU
Energy storage backplane
F511-1140
FRU
Fan board
F541-2112
FRU
Motherboard
F541-3143
FRU
Power distribution board (PDB)
F501-7696
FRU