Sun Blade 6048 Modular System Product Notes
Product Notes
E23072-01
Contents |
Sun Blade 6048 Modular System 2U Expansion Module Specifications
Upgraded Chassis and Midplane Available
Identifying the PCIe 2.0 Midplane
View Component Information Using the CLI
View Component Information Using the Web Interface
Cabinet Doors Must Remain Closed During System Operation
Important Caution for Chassis Midplane Replacement
Power Supply Connections (6615994) (6576346)
Power Supply Watt Meter Feature Not Available for A231 Power Supplies (6614183)
Power Consumption Is Invalid in ILOM if PSU Side Is Under 25A (6438921)
Latest Software Release: CMM Software 3.3.2
Enabling and Disabling the Sun Cooling Door
To Configure the Sun Cooling Door Policy Using the Web Interface
To Configure the Sun Cooling Door Policy Using the CLI
Issues Specific to ILOM 3.0.6.11
ILOM 3.0.6.11 Requires Both Power Supplies to Be Powered Up (6874117)
Issues Specific to ILOM 3.0.3.32
ILOM 3.0.3.32 Displays Power Assert/Deassert Errors in Event Log (6865366)
Reset Server Modules Running ILOM 2.0.3.10 After Updating the CMM to ILOM 3.0.3.32 (6813351)
Moving the CMM to a Different Chassis Can Cause Incorrect Product Data (6821052)
Issues Specific to ILOM 2.0.3.10
Cannot Set Netmask When Running ILOM 2.0.3.10 (6766379)
Issues Specific to ILOM 2.0.3.3
Locate LED Does Not Turn on During Chassis Lamp Test (6713569, 6711416)
Issues Specific to ILOM 2.0.3.2
The stop /CH Command in ILOM 2.0.3.2 is Different Than in ILOM 2.0.3.1 (6679679)
/CH/LOCATE Does Not Turn Off When Set to ON Using the ILOM CLI or ipmitool (6695802)
SP Login Through Web GUI Fails After a New IP Address Is Assigned (6745118)
SP Reports Incorrect FM, NEM, and Server Module Removal and Insertion Events (6744044)
The Tempfail LED and Service LED On the Rear of the Chassis Functionality Is Switched (6745875)
Blade Fan Control Improvement (6903302)
CMM permitted_power Error Message is Unclear (6863970)
start /CH or start /CH/NEMx Does Not Warn That Target Is Already Started (6867739)
Cold Boot of CMM Causes Abnormal Chassis Fan Speed (6876374)
NEM OK LED Should Have Blinking State (6864854)
Issues Fixed in ILOM 3.0.6.11c
CMM Power/OK LED No Longer Works With ILOM 3.0.3.32 (6869525)
Low Fan Speed With Certain Blade Servers (6911651)
Issues Fixed in ILOM 3.0.6.11b
ILOM 3.0.3.32 Displays Incorrect Power Failures in Event Log With Certain PSU Firmware (6865366)
Chassis Amber LED Turns on When PSU0 Is Plugged Into the Chassis (6866727)
CMM Web Interface Slow Response (6853788)
PSU Fan Speed Should Run Slower (6853866)
Need to Include Assembly Number for the CMM (6866148)
CMM OK LED Turns Off During Boot (6474460)
ILOM CMM SP Does Not Display Current Status Information (6516108)
/CH/LOCATE Does Not Turn Off When Set to ON Using the ILOM CLI or ipmitool (6695802)
Locate LED Does not Turn on During Chassis Lamp Test (6713569, 6711416)
SP Reports Incorrect FM, NEM, and Server Module Removal and Insertion Events (6744044)
SP Login Through Web Interface Fails After a New IP Address Is Assigned (6745118)
Cannot Set Netmask When Running ILOM 2.0.3.10 (6766379)
Stop, Start and Reset Commands are Disabled for the Virtualized NEM in the Sun Blade 6000 CMM (6813859 and 6812683)
Power LED Does Not Display Until SP Boots (6464862)
The stop /CH Command Lights the Chassis Alert LED (6678328)
SNMP Trap Destination Port Should Be Configurable (6654887)
Service Processor Information Missing From Installation Guide (6692166)
Copyright © 2011, Oracle and/or its affiliates. All rights reserved.