Locate the SBus card that you want to remove on the back panel of the system board.
The SBus card will be installed in one of the three SBus slots in the system board (Figure 2-18).
If the defective SBus card is located in slot 0, and there is another SBus card installed in slot 1, you must remove the card from slot 1 before removing the defective card from slot 0.
Locate the SBus card on the system board inside the Netra 150 server and unlock the card retainers.
If the SBus card is located in SBus slot 0 or 1, push the card retainers back from the edge of the SBus card. See Figure 2-19.
If the SBus card is located in SBus slot 2, pull the card retainer up. See Figure 2-20. There is only one card retainer for the SBus slot 2.
Grasp the SBus card at both corners, and pull it up to disconnect it from the socket.
Avoid applying force to one end or one side of the board. It damages the connector pins.
Slide the SBus card out of the back panel, and place it on an antistatic surface.