About This Documentation (PDF and HTML)
Overview of the Sun Blade X6275 M2 Server Module Product Notes
System Software Release Features
Integrated Lights Out Manager (ILOM)
Hardware, Firmware, and BIOS Issues
Hardware, Firmware, and BIOS Current Issues
Management and ILOM Current Issues
Capping Power Values in ILOM Web Interface
Reading Server Power Consumption in the CMM
The Server Will Not Boot if the CMM is Off-Line
Locate LED Programmed to Stay On for 30 Minutes (6793865)
Set Port Sharing Error Message Generated When Using SP ILOM Web Interface (6895495)
Green LED Should Slow Blink (1 Hz) During Firmware Upgrade (6862377)
IPMIflash Over USB Interface Fails Due to Unexpected Response to File-upload Command (6856369)
Missing Warning Message While Doing Backup Configuration Without Passphrase (6859295)
Erroneous Chassis Hot Insertion Event Logged After CMM Reboot (6797938)
CMM ILOM Becomes Unresponsive With Multiple CLI Sessions Open (6780171)
CMM ILOM Interface Becomes Unresponsive After Repeated Use (6798257)
Blade Power On Issues With the start /SYS Command (6784708)
SP Network Connection Lost When Issuing Incorrect ipmiflash -I pci Command (6850823)
Powering On Batches of Blades Might Cause a Node to Fail to Power On (6813202)
PCIe EM Native Hot Plug Does Not Work (6804272)
ILOM Power Budget Status Does Not Function Properly When Disabled and Then Enabled (7009654)
ILOM Configurations Are Preserved During Upgrade Even After Specifying "No" (6971164)
If power management policy for a node is set to limit system power using a soft cap, the soft cap settings will not be adhered to if the following is true:
The actual power target cap time limit supplied for the policy is not equal to zero.
The host is powered off, followed by a node SP reboot.
After the SP boots, the host is then powered back on.
If all of the above are true, when the host powers back on the configured power limit will not be adhered to by the system.
After the SP is booted and host is powered on, do one of the following.
In the ILOM web interface:
Under the Power Management —> Limit tab for the node, copy down the settings.
Disable the power limiting option.
Click Save.
Re-enable the power limiting option and enter your settings.
Click Save.
Note - This must be done each time SP is reset and host is powered on.
In the ILOM CLI:
Disable the budget activation state.
Re-enable the budget activation state.