Environmental
Specifications
This topic includes these specifications that apply to both
server configurations:
Table 7 Temperature, Humidity, and Elevation Specifications
|
|
|
|
|
|
|
|
Temperature (maximum)
|
41 to 95°F at 0 to 3000 ft
|
5 to 35°C at 900m
|
-40 to 149°F at 0 to 3000 ft
|
-40 to 65°C at 900m
|
Decrease in maximum temperature: above 3000 ft. (900m),
1.8°F/1000 ft (1°C/300m)
|
Relative humidity
|
10 to 90% at 81°F
|
10 to 90% at 27°C
|
Up to 93% at 100°F
|
Up to 93% at 38°C
|
Maximum wet bulb noncondensing
|
Altitude
|
0 to 9840 ft at 95°F
|
0 m to 3000m at 40°C
|
Up to 39,370 ft
|
Up to 12,000m
|
|
|
Table 8 Shock and Vibration Specifications
|
|
|
Shock |
3G, 11 ms |
Half-sine |
Vibration (vertical) |
0.15G |
5 to 500 HZ swept-sine |
Vibration (horizontal) |
0.10G |
|
|
Table 9 Acoustic Specifications
|
|
|
Sound Power Level - LwAd (1 B=10 dB)
|
7.7 B
|
8.9 B
|
Sound Pressure Level - LpAm (energy average of four bystander
positions)
|
67.8 dBA
|
80.4 dBA
|
|