SAS Ports

The six SAS connectors are located on the drive backplane inside the server.

image:Figure showing the SAS connector pin numbering.

The following table lists the pinouts for the SAS connector.

Segment
Pin
Signal
Note
Signal Segment
(S1 to S7)
S1
Gnd
Second mate
S2
TX+
Transmit from PHY to hard drive
S3
TX-
S4
Gnd
Second mate
S5
RX-
Receive from hard drive to PHY
S6
RX+
S7
Gnd
Second mate
Back-side Signal
(S8 to S14)
S8
Gnd
Second mate
S9
S10
S11
Gnd
Second mate
S12
S13
S14
Gnd
Second mate
Power Segment
(P1 to P15)
P1
3.3V
Not Supported
P2
3.3V
Not Supported
P3
3.3V
Not Supported
P4
Gnd
First mate
P5
Gnd
Second mate
P6
Gnd
Second mate
P7
5.0V
Pre-charge, second mate
P8
5.0V
P9
5.0V
P10
Gnd
Second mate
P11
Reserved
Should be grounded
P12
Gnd
First mate
P13
12.0V
Pre-charge, second mate
P14
12.0V
P15
12.0V