Sun Blade X4-2B Server Module Fails When Launching Remote Console (18962552)
Dual 16 Gigabit/Sec Fibre Channel / 10Gbps FCoE Host Adapter, Emulex
Do Not Use Operating System Tools or Utilities to Manage UEFI Boot Variables (15818528)
One DIMM in a Channel Has an Uncorrectable Error, Other DIMMs Might Have Errors (16181966)
Hot-plugging 2 PCIe EMs Can Cause Correctable Error Messages (15752501)
Do Not Reboot the SP and Host Simultaneously (16346073 and 17013976)
Oracle ILOM restore_status Parameter Shows Partial Status (7167938)
Oracle Recommendations for Drive Slot Population and Virtual Drive Creation (7124194)
PXE-booting Fails When Using Cisco Switch (7149683)
When Running an Emulex HBA in UEFI BIOS Boot Mode, the
Oracle System Assistant Issues
On RHEL5.10 (2.6.18-371.el5) if a reboot on Sun Blade X4-2B Server Module after hot-plugging Metis-Q PEM, then fmadm faulty will report PEM faulted. Applies to PEM Metis-E, IB-CX2, Powerville-UTP and Powerville-MMF. Cause: MPS setting for a hot-plug PCIE device. This issue is also 15752501 - SUNBT7107777. Add a setup item for user to adjust the MPS setting.
Workaround
Change BIOS MPS setting to adjust the "Maxmum Payload" under "IO->PCI Subsystem Settings->PCI Hot-Plug Settings" to "128 Bytes" instead of "Auto"