Excessive Messages Generated for a Power Supply Fan Fault (19951780)

When the fan on a power supply fails, fault messages are repeatedly generated and cleared until you replace the power supply.

On the Oracle Solaris console, the repeated messages are similar to this:

Nov  4 09:58:41 system-name SC Alert: [ID 821027 daemon.alert] Fault
critical: Fault detected at time = Tue Nov  4 14:01:16 2014. The
suspect component: /SYS/PS0 has fault.chassis.device.psu.fail with
probability=100. 

In the Oracle ILOM event log, the multiple entries are similar to this:

53        Tue Nov  4 14:01:16 2014  Fault     Fault     critical
    Fault detected at time = Tue Nov  4 14:01:16 2014. The suspect
    component: /SYS/PS0 has fault.chassis.device.psu.fail with
    probability=100.
352        Tue Nov  4 14:01:06 2014  Sensor    Log       minor
    Power Supply : /SYS/PS0/STATE : Predictive failure : Asserted
351        Tue Nov  4 14:01:06 2014  Sensor    Log       minor
    Power Supply : /SYS/PS0/STATE : Failure detected : Deasserted
350        Tue Nov  4 14:01:00 2014  Fault     UUID_Repaired  minor
    Fault with UUID 9e6ba288-ec5a-48bf-d129-e24a90055231 repaired
349        Tue Nov  4 14:01:00 2014  Fault     Repair    minor
    Component /SYS/PS0 repaired
348        Tue Nov  4 14:01:00 2014  Fault     Repair    minor
    Fault fault.chassis.device.psu.fail on component /SYS/PS0 cleared
347        Tue Nov  4 14:01:00 2014  Sensor    Log       minor
    Power Supply : /SYS/PS0/STATE : Predictive failure : Deasserted
346        Tue Nov  4 14:01:00 2014  Sensor    Log       minor
    Power Supply : /SYS/PS0/STATE : Failure detected : Asserted>

Workaround: The messages will stop repeating when you replace the failing power supply.