Point-to-Point Get Controls

Parameter
Input
Output
SessionId
Session ID
ResourceId
Resource ID
CtrlNum
Point-to-point control number
CtrlMode
SAHP_CTRL_MODE_MANUAL
CtrlType
CtrlState.StateUnion. Oem.MId
0x2A
CtrlState.StateUnion. Oem.BodyLength
0xf
CtrlState.StateUnion. Oem.Body[0]
Connection record number, starting from 1
CtrlState.StateUnion. Oem.Body[1]
Connection list entry number, starting from 1
CtrlState.StateUnion. Oem.Body[2]
Total number of connection records
CtrlState.StateUnion. Oem.Body[3}
The next connection list entry number, or 0xff to indicate that there are no more entries in the list
CtrlState.StateUnion. Oem.Body[4:5]
Connection ID
CtrlState.StateUnion. Oem.Body[6:7]
Location ID A
CtrlState.StateUnion. Oem.Body[8:9]
Port ID A
CtrlState.StateUnion. Oem.Body[10:11]
Location ID B
CtrlState.StateUnion. Oem.Body[12:13]
Port ID B
CtrlState.StateUnion. Oem.Body[15]
Policy byte

Related Information