Point to Point ADS protocol

The program description deals with the following:

Remarks on program function

The data for the PP ADS protocol is updated, i.e. programmed, changed or cleared, with this program. Data which has already been stored can be displayed for information.

This protocol can be used for communications with a background processor.

In the MICROS Retail OSCAR POS program this protocol is used for specific payment types, e.g. hotel credit, as a query to the background processor is necessary here.

Click onto the graphic for further help with programming of a Hotel credit.


Remarks on data fields

The following description deals with all available options for update of this basic data.

As with nearly all other programs the following also applies here:


Baudrate

Field with firmly defined selection options

Select one of the offered baud rates by clicking onto this field and with a second click confirming the selection.

The system offers the following baud rates:

Please note that the baud rate permitted must correspond with the setting of the partner system.


Debug

Field with firmly defined selection options

Select one of the offered debug levels by clicking onto this field and with a second click confirming the selection.

The system offers the following debug levels:

Note:
Only select a value higher than "0" for the debug level if a protocol of communications is required for error analysis. The details are shown in file "errlog" in directory work of the appropriate system unit.


Request timeout

Default = 2000


Read timeout

Default = 2000


Retry time

Default = 200


Ack-Nak time

Default = 0


Max.read retrys

Default = 3


Usage

Entry range permitted: numeric 0 - 9

Enter a value in this field to define how the protocol is to be used.


Modem number

Entry range permitted: alphanumeric max. 40 pos.


Hangup timeout

Default = 60


Modem ID

Default = -1


Index


MICROS Retail Deutschland GmbH
Salzufer 8