WBS/BC200 park automat

The program description deals with the following:

Remarks on program function

The datas for connection of a payment terminal, type WBS/BC200 park automat can be updated, i.e. created, changed or deleted, with this program. Data which has already been stored can also be displayed.

The interface and link to a processing unit must be defined and the device-specific operating mode of the WBS/BC200 park automat is set.

Note:

WPS/BC200 park automat is a device to transfer labeld with amount to the parking system.


Remarks on data fields

All options available for update of the basic data have been described below.

As with nearly all programs the following also applies here:


Debug

Field with firmly defined selection options

Select one of the offered debug levels by clicking on this field and with a second click selecting the level required. 

The system offers the following:

Note:
Only select a value higher than "0" for the debug level if a protocol for communication of the t WBS/BC200 park automat ystem is necessary for error analysis.


Usage

Entry range permitted: numeric, 1 - 9999

Default = 1


Register no.

Gültiger Eingabebereich: alphanumerisch, max. 8 Zeichen

Enter the number or name of the POS, to identify  the connection of the parking automat..


Request timeout

Entry range permitted: numeric, 1 - 0 - 999999999

Default =10000 (Milliseconds.)

Enter a value in this field, to determine the request timeout  of the device..


Input buffer size

Entry range permitted: numeric, 1 - 0 - 9999999

Default =512 (Byte)

Enter a value in this field, to determine the size of the input buffer for the largest received data record.