Oracle® ZFS Storage Appliance 客户服务手册

退出打印视图

更新时间: 2016 年 2 月
 
 

如何定位故障组件 (CLI)

使用 CLI 通过以下过程定位出现故障的组件。

  1. 转到 maintenance hardware 上下文:
    hostname:> maintenance hardware
    
  2. 列出设备组件:
    hostname:maintenance hardware> list
                 NAME        STATE       MODEL             SERIAL      
    chassis-000  hostname    ok          Sun Storage 7320  unknown     
    chassis-001  000000000C  faulted     J4410             000000000C  
    
  3. 选择机箱并列出其组件:
    hostname:maintenance hardware> select chassis-001
    hostname:maintenance chassis-001> list
                             disk
                              fan
                              psu
                             slot
    
  4. 选择组件类型并显示所有可用的磁盘:
    hostname:maintenance chassis-001> select disk
    hostname:maintenance chassis-001 disk> show
    Disks:
              LABEL   STATE       MANUFACTURER  MODEL             SERIAL      
    disk-000  HDD 0   ok          ST3500630NS   ST3500630NS       9QG1ACNJ    
    disk-001  HDD 1   faulted     ST3500630NS   ST3500630NS       9QG1A77R    
    disk-002  HDD 2   ok          ST3500630NS   ST3500630NS       9QG1AC3Z    
    disk-003  HDD 3   ok          ST3500630NS   ST3500630NS       9QG1ACKW    
    disk-004  HDD 4   ok          ST3500630NS   ST3500630NS       9QG1ACKF    
    disk-005  HDD 5   ok          ST3500630NS   ST3500630NS       9QG1ACPM    
    disk-006  HDD 6   ok          ST3500630NS   ST3500630NS       9QG1ACRR    
    disk-007  HDD 7   ok          ST3500630NS   ST3500630NS       9QG1ACGD    
    disk-008  HDD 8   ok          ST3500630NS   ST3500630NS       9QG1ACG4    
    disk-009  HDD 9   ok          ST3500630NS   ST3500630NS       9QG1ABDZ    
    disk-010  HDD 10  ok          ST3500630NS   ST3500630NS       9QG1A769    
    disk-011  HDD 11  ok          ST3500630NS   ST3500630NS       9QG1AC27    
    disk-012  HDD 12  ok          ST3500630NS   ST3500630NS       9QG1AC41    
    disk-013  HDD 13  ok          ST3500630NS   ST3500630NS       9QG1ACQ5    
    disk-014  HDD 14  ok          ST3500630NS   ST3500630NS       9QG1ACKA    
    disk-015  HDD 15  ok          ST3500630NS   ST3500630NS       9QG1AC5Y    
    disk-016  HDD 16  ok          ST3500630NS   ST3500630NS       9QG1ACQ2    
    disk-017  HDD 17  ok          ST3500630NS   ST3500630NS       9QG1A76S    
    disk-018  HDD 18  ok          ST3500630NS   ST3500630NS       9QG1ACDY    
    disk-019  HDD 19  ok          ST3500630NS   ST3500630NS       9QG1AC3Y    
    disk-020  HDD 20  ok          ST3500630NS   ST3500630NS       9QG1ACG6    
    disk-021  HDD 21  ok          ST3500630NS   ST3500630NS       9QG1AC3X    
    disk-022  HDD 22  ok          ST3500630NS   ST3500630NS       9QG1ACHL    
    disk-023  HDD 23  ok          ST3500630NS   ST3500630NS       9QG1ABLW    
    

    注 - 磁盘驱动器的 RPM(revolutions per minute,每分钟转数)也显示在输出中。但是,在以上示例中 RPM 已被截断。
  5. 选择故障磁盘并打开定位器 LED 指示灯:
    hostname:maintenance chassis-001 disk> select disk-001
    hostname:maintenance chassis-001 disk-001> set locate=true
                           locate = true (uncommitted)
    hostname:maintenance chassis-001 disk-001> commit