This procedure provides instructions to verify Oracle 6.8 TB NVMe SSD v3 operation on the host for supported Oracle Solaris and Oracle Linux operating systems. Verify Oracle 6.8 TB NVMe SSD v3 operation using Oracle Hardware Management Pack utility CLI tools.
Before You Begin
Verify that Oracle Hardware Management Pack is installed on the host.
For CLI command instructions, refer to Oracle Hardware Management Pack documentation at https://www.oracle.com/goto/ohmp/docs.
Ensure that you have access to the server (either directly or over the network).
Verify that the Fault-Service Required 6.8 TB NVMe SSD status indicator is not lit and that the green Power status indicator is lit on the 6.8 TB NVMe SSDs that you updated. LED status indicators are: Green (operational), Amber (faulty disk ), Blue (SSD has been prepared for removal).
Refer to Oracle 6.8 Tbyte, 2.5-inch, NVMe Solid State Drive Specification.
For detailed instructions, refer to the server installation guide. For example, to log in to the target system through SSH or through Oracle ILOM Remote System Console Plus, do one of the following:
Type: ssh root@hostname, where hostname can be the DNS name or the IP address for the server host.
To launch an Oracle ILOM Remote System Console Plus session, refer to Launching Remote KVMS Redirection Sessions in the server administration guide.
Start an Oracle ILOM serial console session, type:
-->start /HOST/console
Are you sure you want to start /HOST/console (y/n)? y
You issue Oracle Hardware Management Pack commands from the operating system command-line interface.
In the following example, devices are enumerated in the output returned by the above command.
# fwupdate list controller ================================================== CONTROLLER ================================================== ID Type Manufacturer Model Product Name FW Version ----------------------------------------------------------------------------- c0 NVMe Samsung 0xa824 SAMSUNG MZWLR7T6HALA-00AU3MPK94R5Q c1 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 c2 HDC Intel 0xa182 0x4873 - c3 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 c4 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 c5 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1R104 c6 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1R104 c7 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1R103 c8 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1R103 c9 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 c10 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 c11 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30
In the above example, 6.8 TB NVMe SSD controllers c0 to c6 are enumerated in the output returned by the above command.
See Minimum Supported Oracle 6.8 TB NVMe SSD v3 Firmware Version.
To identify NVMe controllers and current firmware versions, type: # nvmeadm list -v
To identify NVMe controllers that have updated firmware, view the Firmware Revision row in the output from the nvmeadm list -v command.
In the following example, controller SUNW-NVME-2 shows firmware version 2CV1RC30 in the output returned by the above command.
# nvmeadm list -v SUNW-NVME-1 PCI Vendor ID: 0x144d Serial Number: S64TNE0N800033 Model Number: SAMSUNG MZWLR7T6HALA-00AU3 Firmware Revision: MPK94R5Q Number of Namespaces: 32 SUNW-NVME-2 PCI Vendor ID: 0x8086 Serial Number: PHAB011200LV7P6GGN Model Number: INTEL SSDPF2KX076T9S Firmware Revision: 2CV1RC30 Number of Namespaces: 128
To check the selected 6.8 TB NVMe SSD health and SMART (Self-Monitoring, Analysis, and Reporting Technology) information, type: # nvmeadm getlog -h
Ensure that the 6.8 TB NVMe SSDs have remaining drive life (Percentage Used) in the output returned by the above command.
# nvmeadm getlog -h SUNW-NVME-1 SMART/Health Information: Critical Warning: 0 Temperature: 315 Kelvin Available Spare: 100 percent Available Spare Threshold: 10 percent Percentage Used: 0 percent Data Unit Read: 0x2fa1c314 of 512k bytes. Data Unit Written: 0x23bd12c7 of 512k bytes. Number of Host Read Commands: 0x3f0bb9308 Number of Host Write Commands: 0x1c2433434 Controller Busy Time in Minutes: 0x525 Number of Power Cycle: 0x56e Number of Power On Hours: 0x55f Number of Unsafe Shutdown: 0x307 Number of Media Errors: 0x0 Number of Error Info Log Entries: 0x0 SUNW-NVME-2 SMART/Health Information: Critical Warning: 0 Temperature: 310 Kelvin Available Spare: 99 percent Available Spare Threshold: 10 percent Percentage Used: 1 percent Data Unit Read: 0x138a818a of 512k bytes. Data Unit Written: 0x2d71a25d of 512k bytes. Number of Host Read Commands: 0xe75e59ca Number of Host Write Commands: 0x7a604b45c Controller Busy Time in Minutes: 0xe0 Number of Power Cycle: 0x89 Number of Power On Hours: 0x1443 Number of Unsafe Shutdown: 0x78 Number of Media Errors: 0x0 Number of Error Info Log Entries: 0x0
Minimum Supported Oracle 6.8 TB NVMe SSD v3 Firmware Version
Oracle Hardware Management Pack documentation at: https://www.oracle.com/goto/ohmp/docs