Oracle® Communications EAGLE Database Administration - GWS User's Guide Release 46.6 E93314 Revision 1 |
|
![]() Previous |
![]() Next |
This procedure is used to add a screen set to the database using the ent-scrset
command. The parameters used by the ent-scrset
command are shown in the Gateway Screening Attributes section. The general rules that apply to configuring gateway screening entities are shown in the Gateway Screening Configuration section.
A maximum of 255 screen sets can be configured in the database. If the database contains 255 screen sets, any attempt to add another screen set with the ent-scrset
command will be rejected. If the database contains 255 screen sets, and you wish to add another screen set, a current screen set must be removed or changed. To remove a screen set, perform the Removing a Screen Set procedure. To change an existing screen set, perform the Changing a Screen Set procedure.
The examples in this procedure are used to add the screen set data shown in Table 13-1 and based on the example configurations shown in Figure 2-3 through Figure 2-9.
Table 13-1 Example Gateway Screening Screen Set Configuration Table
Screen Set Name | Next Screening Function Identifier | Next Screening Reference | DESTFLD |
---|---|---|---|
gws1 | opc | gws4 | No |
gws2 | blkopc | gws5 | No |
ls01 | sio | ls02 | Yes |
wrd1 | dpc | iec | Yes |
fld1 | opc | fld2 | No |
isp1 | opc | isp1 | No |
tup1 | opc | tup1 | No |
The screen set can reference one of the following screens.
Verifying the Gateway Screening Configuration
Enter the following commands to verify that these screens are in the database.
rtrv-scr-opc:all=yes
rtrv-scr-blkopc:all=yes
rtrv-scr-sio:all=yes
rtrv-scr-dpc:all=yes
rtrv-scr-blkdpc:all=yes
Gateway Screening Configuration Procedures
If the desired screen is not in the database, perform one of these procedures to add the desired screen to the database or change an existing screen in the database.
Figure 13-1 Adding a Screen Set
Sheet 1 of 3
Sheet 2 of 3
Sheet 3 of 3