4.42 chg-card
- Change the configuration of a card in the database from an IPLIMx configuration to an IPSG configuration and from an E5-ENET-B or SLIC card.
- Configure the type of EPAP data (DN or IMSI) that is loaded to an E5-SM8G-B or SLIC card.
- If the IPSG application is running on SLIC hardware,
the
chg-card
command can be optionally used to change the data type from 'gtt' to 'nosccp' and vice-versa.
Parameters
- loc (mandatory)
- The card location as stenciled on the shelf of the
system.
- Range:
- 1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
- data (optional)
-
Type of OAM/MPS data that can be loaded on an E5-SM8G-B or SLIC card.
- Range:
-
- dn
- only DN related data from EPAP is loaded on the card
- epap
- all RTDB data (DN+IMSI) from EPAP are
loaded on the card
Note:
The epap value cannot be specified when the EPAP Data Split feature is ON. - elap
- ELAP data are loaded on the card.
- gtt
- Only OAM data, including GTT data, are loaded on the card. This card will not load any ELAP or EPAP data at all.
- imsi
- Only IMSI related data from EPAP is loaded on the card
- nosccp
- Only OAM data, excluding GTT data is
loaded on the card. No GTT or MPS data will be downloaded on the card. This
value (=nosccp) of the
data parameter is
valid only for IPSG card(s) with the
type=slic.
Note:
The nosccp value signifies the absence of SCCP functionality on the IPSG card, and that it behaves as a regular IPSG card.
Example
chg-card:loc=1105:nappl=ipsg
chg-card:loc=1305:type=enetb
chg-card:loc=1201:data=imsi
chg-card:loc=1101:type=slic
Dependencies
The card location specified by the loc parameter cannot be 1113-1118, xy09, or xy10 where x is the frame and y is the shelf.
The specified shelf location must be provisioned and present in the frame.
The Shelf table is corrupt or cannot be found.
The IMT (Card) table is corrupt or cannot be found.
Only M2PA associations can be configured for the IP link host address for the card indicated by the loc parameter value. M3UA IP associations are not supported.
If the HIPR2 High Rate Mode feature is turned off, then the sum of the TPS values assigned to all linksets in the system must be less than or equal to 500,000. If the HIPR2 High Rate Mode feature is turned on, then the sum of the TPS values assigned to all linksets in the system must be less than or equal to 750,000. If the HIPR2 High Rate Mode and 1M System TPS features are turned on, then the sum of the TPS values assigned to all linksets in the system must be less than or equal to 1,000,000.
The resulting total TPS of all signaling links configured for an E5-ENET-B or SLIC card when the type=enetb parameter is specified cannot exceed 6500 TPS. The resulting total TPS of all signaling links configured for a SLIC card when the type=slic parameter is specified cannot exceed 12,000 TPS
A SLIC card must be installed at the location indicated by the loc parameter.
A value of ipsg must be specified for the nappl parameter.
The card in the location indicated by the loc parameter must already be equipped.
The value specified by the loc parameter must be within the allowed range.
The Link table is corrupt or cannot be found.
The loc parameter must be specified.
All links on the SLIC card must have a matching association configured. For
IPSG-hosted associations, a link and association are matched using the aname parameter for the ent-slk
command.
The nappl or type parameter must be specified.
If DN or IMSI is specified for the data parameter for VSCCP, the EPAP Data Split feature must be turned on.
Note:
The DATA parm is valid only for SLIC IPSG cards, and not ENET/ENETB IPSG cards.If ELAP or EPAP is specified for the data parameter for VSCCP, the Dual ExAP Config feature must be enabled.
When data=gtt is specified for VSCCP, either Dual ExAP Config must be enabled or EPAP Data Split feature must be turned ON.
The data=gtt parameter cannot be specified for VSCCP if an IP link has been configured for the card.
To provision card type=ENETB or SLIC, the shelf FAN bit must be turned ON for the card's shelf.
If the IPSG32 GPL is running on the location specified by the loc parameter, then data=gtt and data=nosccp are the only valid values for the DATA parameter. If the GPL is anything but IPSG32 GPL, data=nosccp cannot be used for the card on that location.
If card is type=SLIC with data=GTT and is changed to type=ENET/ENETB, then data must be changed to NOSCCP first.
A GTT-enabled IPSG card can only have 32 equipped SS7 links. A SLIC IPSG card with more than 32 equipped SS7 links cannot be a GTT-enabled IPSG card.
The data parameter can only be specified for IPSG application running on SLIC card.
Notes
If a SLIC card is plugged into a slot provisioned for E5-ENET-B, this command can be used to change the card type from enet to slic or enetb to slic. The card must be manually inhibited first in order to allow the command to be processed.
Output
chg-card:loc=1206:nappl=ipsg
rlghncxa03w 10-03-01 11:11:28 EST EAGLE 42.0.0
CHG-CARD: MASP A - COMPLTD
;