4.52 chg-e1
Use this command to change an interface for an E1 card in the system. An E1 card can consist of an E5-E1T1-B card used as an E1 or SE-HSL card.
Parameters
- e1port (mandatory)
- E1 port number. The value must be an E1 port that has already been configured with an E1 interface on the specified E1 card.
- loc (mandatory)
- The card location as stenciled on the shelf of the system.
- Range:
- 1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
- minsurate (optional)
- Minimum signal unit rate. The minimum number of SUs present on a link that are uniformly distributed.
Example
chg-e1:loc=1205:e1port=1:crc4=off:cas=on:encode=hdb3:si=2:sn=12
chg-e1:loc=1205:e1port=2:encode=ami
chg-e1:loc=1205:e1port=1:minsurate=1000
chg-e1:loc=1201:e1port=2:e1tsel=external
Dependencies
At least one optional parameter must be specified.
The specified card location (loc parameter) must be equipped.
The card specified by the loc parameter must be a LIME1 card type.
The port specified by the e1port parameter must already be equipped with an E1 interface.
If the value specified for the loc parameter indicates an E1 card, then all signaling links that are serviced by the card must be deactivated (see the dlt-slk
command) before the values for the crc4, cas, encode, and e1tsel parameters can be changed.
The encode=ami parameter is supported only for cards used as E1 cards (not as SE-HSL cards).
The linkclass=unchan parameter must be specified before the minsurate parameter can be specified.
The E1/T1 table must be accessible.
The Card table must be accessible.
HIPR2 cards must be equipped in card locations xy09 and xy10 (x is the frame, y is the shelf) on each EAGLE shelf that contains one or more E5-E1T1-B cards.
The Shelf FAN bit must be turned ON for the shelf on which an E5-E1T1-B card is being used as an E1 or SE-HSL card.
Card locations 1113 - 1118 (E5-MASP and E5-MDAL cards) cannot be specified as values for the loc parameter.
Locations xy09 and xy10, where x is the frame and y is the shelf, cannot be specified as values for the loc parameter.
Notes
External timing is derived from the EAGLE High-Speed Master Clock (1.544 MHz for T1 or 2.048 MHz for E1); therefore, the Master Timing feature is required. Line timing is derived from its received data stream, if present.
Output
chg-e1:loc=1205:e1port=2:encode=ami
rlghncxa03w 04-01-20 09:07:58 EST EAGLE 31.3.0
CHG-E1: MASP A - COMPLTD
;