4.624 tst-e1

Use this command to test E1 ports. The command is rejected if a loopback test is not compatible with the port type. This command can be used with E5-E1T1-B cards.

Parameters

e1port (mandatory)
E1 port number. The value must be an E1 port that has already been configured with an E1 interface on the specified card.
Range:
1 - 8
loc (mandatory)
Card location. The card location as stenciled on the shelf of the system.
Range:
1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
action (optional)
Indicator of command action to stop or start a test.
Range:
start
stop
Default:
start
loopback (optional)
Select loopback test type.
Range:
line
lxvr
local transceiver
payload
Default:
lxvr

Example

tst-e1:e1port=1:loc=1203:loopback=lxvr

tst-e1:e1port=1:loc=1203:action=stop

Dependencies

This command cannot be entered during upgrade.

The value specified for the loc parameter must indicate an E5-E1T1-B card with card type LIME1.

The card in the specified card location (loc parameter) must be equipped.

The card in the specified card location (loc parameter) must be in service.

The specified E1 port (e1port parameter) on the card (loc parameter) must have a defined E1 interface.

All signaling links that provide timeslots serviced by E1 interfaces on the specified card must be deactivated before this command can be entered. None of the signaling links can be running link diagnostic tests (tst-slk and act-cdl) when this command is entered.

Only one port test can be running on an E1 port (e1port parameter) at one time.

When the action=stop parameter is specified, the loopback parameter cannot be specified.

The E1/T1 table must be accessible.

The action=stop parameter can be specified only when a port test is running.

Notes

Only one port test can be performed at a time on an E1 port. When a port test is in progress on an E1 port, subsequent test requests are rejected.

Output

tst-e1:e1port=1:loc=1203:loopback=lxvr

    rlghncxa03w 05-01-07 16:19:08 EST  EAGLE5 33.0.0
    Command Accepted: Test Port message is sent. 
;
    rlghncxa03w 05-01-07 16:19:08 EST  EAGLE5 33.0.0
    Command Completed. 
;
tst-e1:e1port=1:loc=1203:action=stop

    rlghncxa03w 05-01-07 16:19:08 EST  EAGLE5 33.0.0
    Command Accepted: Stop Port test message is sent. 
;
    rlghncxa03w 05-01-07 16:19:08 EST  EAGLE5 33.0.0
    Command Completed. 
;