4.193 dlt-csl

Use this command to delete an existing entry from the Common Screening List (CSL). The Common Screening List commands are used to tailor certain types of general screening information to specific features.

Parameters

Note:

Either the ds parameter or the pc parameter must be specified in the command. Both parameters cannot be specified in the same command.
ds (optional)
Digit string. A unique string of digits that is used by the specified screening feature.
Range:
1 - 15 hexadecimal digits. Valid digits are 0-9, a-f, A-F
  • 1-6 digits—Prepaid IDP Query Relay CCNC list
  • 1-15 digits—Prepaid IDP Query Relay GT list
  • 1-10 digits—Prepaid IDP Query Relay SKBCSM list
  • 4 digits—IDP Screening for Prepaid SKTS list
  • 1-15 digits—IDP Screening for Prepaid INSL list
  • 1-15 digits—VFLEX VMPFX list
  • 1-6 digits—Info Analyzed Relay Base CCNC list
  • 1-15 digits—Info Analyzed Relay Base GT list
  • 2 digits—Info Analyzed Relay Base TRIG list
  • 1 - 15 digits — EIR imsipfx list

Table 4-23  lists valid hexadecimal values for the Info Analyzed Relay Base TRIG list DS entries.

feature (optional)
Feature name. The name of the enabled screening feature for which the command is entered.
Range:
azzzzzzzzzzzzzzzzzzzzzzzz

1 alphabetic character followed by up to 24 optional alphanumeric characters, including spaces and special characters, enclosed in double quotation marks (" ").

Enter enough of the feature name to make the name unique if two features begin with the same word or acronym. The following feature names are valid for this command:

  • EIR
  • IDP Screening for Prepaid
  • IDP Service Key Routing
  • Info Analyzed Relay Base
  • Prepaid IDP Query Relay
  • VFLEX 
list (optional)
Name of the Common Screening List associated with the feature.

This parameter must be specified when the feature uses more than one type of Common Screening List.

Range:
ccnc
CC+NC List
delpfx
Delete Prefix List
gt
Global Title List
imsipfx
IMSI Screening Prefix List
insl
In Network Subscriber List
npbypass
SIP NPBYPASS List
skbcsm
SK+BCSM List
skts
Service Key + Teleservice List
trig
Trigger List
vmpfx
Voice Mail Prefix List
opcdpc
OPC + DPC List

The following screening lists are valid for the indicated features:

  • ccnc, gt—Prepaid IDP Query Relay and Info Analyzed Relay Base 
  • imsipfx --- EIR

    Note:

    If list argument is not specified in this command for EIR feature then list = imsipfx by default is taken
  • insl, skts—IDP Screening for Prepaid
  • npbypass — SIP Number Portability
  • skbcsm—Prepaid IDP Query Relay and IDP Service Key Routing
  • trig—Info Analyzed Relay Base
  • vmpfx—VFLEX
  • opcdpc—Prepaid IDP Query Related

The delpfx list is not supported at this time. This list should only be used by Oracle personnel.

pc (optional)
ANSI point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Synonym:
pca
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

When chg-sid:pctype=ansi is specified, ni = 000 is not valid.

When chg-sid:pctype=ansi is specified, nc = 000 is not valid if ni = 001–005.

When chg-sid:pctype=ansi is specified, nc = 000 is valid if ni = 006–255.

The point code 000-000-000 is not a valid point code.

Note:

See Point Code Formats and Conversion for a detailed description of point code formats, rules for specification, and examples.
pc/pca/pci/pcn/pcn24 (optional)
Point code. The ds parameter or a point code parameter must be specified.
pci (optional)
ITU international point code with subfields zone-area-id.
Range:
0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

zone—0–7

area—000–255

id—0-7

The point code 0-000-0 is not a valid point code.

pcn (optional)
ITU national point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc).
Range:
s-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix—s-

nnnnn—0-16383

gc—aa-zz

m1-m2-m3-m4—0-14 for each member; values must sum to 14

pcn24 (optional)
24-bit ITU national point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

msa—000–255

ssa—000–255

sp—000–255

dpc(optional)
ANSI destination point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Synonym:
dpca
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

The point code 000-000-000 is not a valid point code.

dpc/dpca/dpci/dpcn/dpcn24/dpcn16 (optional)
Destination point code.
dpci (optional)
ITU international destination point code with subfields zone-area-id. The prefix subfield indicates a spare point code (prefix-zone-area-id).
Range:
s-, 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix-s

zone-0-7

area-000-255

id-0-7

The point code 0-000-0 is not a valid point code.

dpcn (optional)
ITU national destination point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc,m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc).
Range:
s-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix-s-

nnnnn-0-16383

gc-aa-zz

m1-m2-m3-m4-0-14 for each member; values must sum to 14

dpcn24 (optional)
16-bit ITU national point code with subfields unit number sub number area main number area (un-sna-mna).
Range:
000-255
Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

msa-000-255

ssa-000-255

sp-000-255

dpcn16 (optional)
24-bit ITU national destination point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Range:
000-127

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

un---000---127

sna---000---15

mna---000---31

opc (optional)
ANSI originating point code with subfields network indicator-network cluster-network cluster member (ni-nc-ncm).
Synonym:
opca
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

The point code 000-000-000 is not a valid point code.

opc/opca/opci/opcn/opcn24/opcn16 (optional)
Originating point code.
opci (optional)
ITU international destination point code with subfields zone-area-id. The prefix subfield indicates a spare point code (prefix-zone-area-id).
Range:
s- , 0-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix-s

zone-0-7

area-000-255

id-0-7

The point code 0-000-0 is not a valid point code.

opcn (optional)
New ITU national originating point code in the format of a 5-digit number (nnnnn); or 2, 3, or 4 numbers (members) separated by dashes (m1-m2-m3-m4) as defined by the chg-stpopts:npcfmti flexible point code option. A group code must be specified when the ITUDUPPC feature is turned on (nnnnn-gc, m1-m2-m3-m4-gc). The prefix subfield indicates a spare point code (prefix-nnnnn, prefix-nnnnn-gc, prefix-m1-m2-m3-m4, prefix-m1-m2-m3-m4-gc).
Range:
s-, 0-16383, aa-zz

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

prefix-s-

nnnnn-0-16383

gc-aa-zz

m1-m2-m3-m4-0-14 for each member; values must sum to 14

opcn24 (optional)
24-bit ITU national originating point code with subfields main signaling area-sub signaling area-signaling point (msa-ssa-sp).
Range:
000-255

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

msa-000-255

ssa-000-255

sp-000-255

opcn16 (optional)
16-bit ITU national point code with subfields unit number sub number area main number area (un-sna-mna).
Range:
000-127

Specify a valid value for each subfield of the point code, and separate the subfields with a dash (-).

un---000---127

sna---000---15

mna---000---31

pn (optional)
Part Number. The 9-digit "893xxxxxx" part number of the feature for which the command is entered. The rtrv-ctrl-feat command description shows the part number in the command output example.
Range:
893000000 - 893999999

The first 3 digits are 893. Do not separate the digits with dashes or spaces. The following part numbers are valid for this command:

  • 893012301— EIR
  • 893015501—IDP Screening for Prepaid
  • 893016001—Prepaid IDP Query Relay
  • 893034201—Info Analyzed Relay Base
  • 893016701—VFLEX

Example

dlt-csl:feature="IDP Screening for Prepaid":list=insl:ds=246810

dlt-csl:pn=893015501:list=skts:ds=36ab

dlt-csl:feature="VFLEX":list=vmpfx:ds=123456789abcdEF

dlt-csl:pn=893040601:list=npbypass:ds=0000000056

dlt-csl:feature="EIR":list=imsipfx:ds=4012312312

dlt-csl:pn=893016001:list=opcdpc:dpci=4-5-6

dlt-csl:pn=893016001:list=opcdpc:dpci=4-5-6:opci=2-1-2

Dependencies

An enabled feature must be specified using a valid part number (pn parameter) or feature name (feature parameter). The specified feature must use a Common Screening List.

The value specified for the feature parameter must be a valid feature name for a feature that uses a Common Screening List. The feature name must be specified as it appears in the rtrv-ctrl-feat command output. Enough of the name must be specified to make the name unique when two features begin with the same word or acronym.

The feature that is specified in the feature parameter must be enabled.

The list parameter must be specified for features that use more than one type of screening list.

The value specified for the list parameter must be valid for the specified screening feature.

The specified screening list entry must exist in the screening list that is used by the feature.

The following parameters are allowed with the indicated common screening list type:

  • list=gt ds parameter
  • list=ccncds parameter
  • list=imsipfx--- ds parameters
  • list=skbcsmds parameter
  • list=sktsds parameter
  • list=inslds parameter
  • list=vmpfxds parameter 
  • list=trigds parameter 

The Common Screening List table is corrupt or cannot be found.

The opc/dpc, pc and ds parameters cannot be specified together in the command.

The parameter p1 or p2 cannot be specified in the command.

For IDPR service, if list type opcdpc given, then opc/dpc parameter must be specified.

Notes

None

Output

dlt-csl:pn=893015501:list=insl:ds=123456789abcdEF

    tekelecstp 05-08-21 15:18:41 EST  EAGLE 34.3.0
    INSL List table is (5 of 50) 10% full
    DLT-CSL: MASP A - COMPLTD 
;
dlt-csl:pn=893040601:list=npbypass:ds=0000000012

tekelecstp 12-06-25 15:29:14 EST EAGLE 45.0.0
dlt-csl:pn=893040601:list=npbypass:ds=0000000012
Command entered at terminal #4.
PFX List (2 of 1000) 1%
DLT-CSL: MASP A-COMPLTD
;