4.398 rept-stat-cdt

Use this command to display the customer-defined troubles. The Customer-Definable Alarms feature can be used to connect up to 10 external devices to the system for alarm reporting. These devices are defined in the system database as customer-defined troubles, and they are monitored so that any change in the state of these devices is reported as an unsolicited alarm message (UAM).

Parameters

This command has no parameters.

Example

rept-stat-cdt

Dependencies

No other status command can be in progress when this command is entered.

Notes

These troubles are customer-defined and configured by the factory.

Output

rept-stat-cdt

    rlghncxa03w 04-01-07 20:20:43 EST  EAGLE 31.3.0
    ID                  ALARM STATUS
     1    *C 0058  Critical Customer Trouble detected
     2    *C 0050  Critical Holdover Clock trouble detected
     3    *C 0058  Critical Customer Trouble detected
     4    *C 0058  Critical Customer Trouble detected 
     5  I ** 0059  Major Customer Trouble detected
     6    ** 0052  Major Holdover Clock trouble detected
     7    ** 0059  Major Customer Trouble detected
     8    ** 0059  Major Customer Trouble detected 
     9  I *  0060  Minor Customer Trouble detected
    10    *  0054  Minor Holdover Clock trouble detected
    11    *  0060  Minor Customer Trouble detected
    12    *  0060  Minor Customer Trouble detected
    13    *  0060  Minor Customer Trouble detected
    14  I *  0060  Minor Customer Trouble detected
    15    *  0060  Minor Customer Trouble detected
    16    *  0060  Minor Customer Trouble detected 
;

Legend

  • ID—The customer defined trouble ID number followed by the status of the customer-defined trouble.
  • ALARM STATUS—The status of the alarm for the specified device.