4.398 rept-stat-cdt
Use this command to display the customer-defined troubles. The Customer-Definable Alarms feature can be used to connect up to 10 external devices to the system for alarm reporting. These devices are defined in the system database as customer-defined troubles, and they are monitored so that any change in the state of these devices is reported as an unsolicited alarm message (UAM).
Parameters
This command has no parameters.
Example
rept-stat-cdt
Dependencies
No other status command can be in progress when this command is entered.
Notes
These troubles are customer-defined and configured by the factory.
Output
rept-stat-cdt
rlghncxa03w 04-01-07 20:20:43 EST EAGLE 31.3.0
ID ALARM STATUS
1 *C 0058 Critical Customer Trouble detected
2 *C 0050 Critical Holdover Clock trouble detected
3 *C 0058 Critical Customer Trouble detected
4 *C 0058 Critical Customer Trouble detected
5 I ** 0059 Major Customer Trouble detected
6 ** 0052 Major Holdover Clock trouble detected
7 ** 0059 Major Customer Trouble detected
8 ** 0059 Major Customer Trouble detected
9 I * 0060 Minor Customer Trouble detected
10 * 0054 Minor Holdover Clock trouble detected
11 * 0060 Minor Customer Trouble detected
12 * 0060 Minor Customer Trouble detected
13 * 0060 Minor Customer Trouble detected
14 I * 0060 Minor Customer Trouble detected
15 * 0060 Minor Customer Trouble detected
16 * 0060 Minor Customer Trouble detected
;
Legend
- ID—The customer defined trouble ID number followed by the status of the customer-defined trouble.
- ALARM STATUS—The status of the alarm for the specified device.