4.630 tst-t1

Use this command to test T1 ports. The command is rejected if a loopback test is not compatible with the port type.

Note:

This command can be entered for E5-E1T1-B cards.

Parameters

loc (mandatory)
The card location as stenciled on the shelf of the system.
Range:
1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
t1port (mandatory)
T1 port number. The value must be a T1 port that has already been configured with a T1 interface on the specified card.
Range:
1 - 8
action (optional)
Indicator of command action to stop or start a test.
Range:
start
stop
Default:
start
loopback (optional)
Select loopback test type.
Range:
line
lxvr
local transceiver
payload
feline
far end line
fepayload
far end payload
Default:
lxvr

Example

tst-t1:t1port=1:loc=1203:loopback=lxvr

tst-t1:t1port=1:loc=1203:action=stop

Dependencies

This command cannot be entered during upgrade.

The value specified for the loc parameter must indicate an E5-E1T1-B card with card type LIMT1.

The card in the location specified by the loc parameter must be equipped.

The card in the location specified by the loc parameter must be in service.

The T1 port specified by the t1port parameter must have a defined T1 interface.

All signaling links that provide timeslots serviced by T1 interfaces on the specified card must be deactivated before this command can be entered. None of the signaling links can be running link diagnostic tests (tst-slk and act-cdl commands) when this command is entered.

Only one port test can be running on the T1 port specified by the t1port parameter at one time.

The E1/T1 Port table must be accessible.

The action=stop parameter can be specified only when a port test is running.

If the action=stop parameter is specified, a value of feline or fepayload must be specified for the loopback parameter.

If the action=stop parameter is specified, and a value of feline or fepayload is specified for the loopback parameter, then there cannot be an active loopback for the T1 span, or the active loopback must be the one specified in the tst-t1:action=stop command.

Notes

Only one port test can be performed at a time on a T1 port. When a port test is in progress on a T1 port, subsequent test requests are rejected.

If a loopback type of feline or fepayload is specified, then the loopback requests are sent to the far end. No response is given from the far end to indicate if the request was acted upon or received. The local card which hosts the T1 span in the EAGLE does not instrument the loopback locally but maintains knowledge of the far end loopback request.  If the local card boots, this knowledge is lost by the card.

To maintain the far end loopback states, if the T1 card with an active feline or fepayload test boots, the card loses any knowledge of the Far End loopback request, but the OAM retains that knowledge. If the OAM boots, the T1 card updates the OAM with its last known loopback state. If both the T1 card and the active OAM card boot while a Far End Loopback is active, then there is no way of determining the T1 state; however, a tst-t1:action=stop:action=(feline or fepayload) command can still be sent.

Output

tst-t1:t1port=1:loc=1203:loopback=lxvr

    rlghncxa03w 05-01-07 16:19:08 EST  EAGLE5 33.0.0
    Command Accepted: Test Port message is sent. 
;
    rlghncxa03w 05-01-07 16:19:08 EST  EAGLE5 33.0.0
    Command Completed. 
;
tst-t1:t1port=1:loc=1203:action=stop

    rlghncxa03w 05-01-07 16:19:08 EST  EAGLE5 33.0.0
    Command Accepted: Stop Port test message is sent. 
;
    tekelecstp 03-12-16 14:31:23 EST  EAGLE5 33.0.0
    Command Completed. 
;

Related Topics