Electrical
Specifications
|
|
Voltage
|
200 to 240 VAC
|
Frequency
|
50 to 60 Hz
|
Maximum operating input current at 200 VAC (per cord)
|
5.2 A
|
Maximum operating input power at 200 VAC
|
1048W
|
Maximum standby power
|
23.8W
|
Idle AC input power (maximum configuration)
Maximum server configuration specification under nominal
temperature and voltage conditions (two 4.267-GHz S7 processors with
sixteen 64GB DDR4 DIMMs, twenty-two SAS and four NVMe SFF drives,
one internal HBA card, and 6 PCIe cards).
|
565W
|
Peak AC input power running MGRID (maximum configuration)
|
889W
|
Idle AC input power (minimum configuration)
Minimum server configuration specification under nominal
temperature and voltage conditions (two 4.267-GHz S7 processors,
eight 16-GB DDR4 DIMMs, no drives, one internal HBA card, and no
PCIe cards).
|
298W
|
Peak AC input power running MGRID (minimum configuration)
|
591W
|
Maximum heat dissipation
|
3576 BTU/hr
3772 KJ/hr
|
|
For information on power specifications, use the power calculator
at:
http://www.oracle.com/us/products/servers-storage/sun-power-calculators