Configuration Metrics

This section provides information about the following configuration metrics:

System Configuration Metrics

The System Configuration metrics are collected from an Oracle Hardware System target every 24 hours. The metrics provide an overview of the Oracle Hardware System target's configurable parameters. The following table explains the different metrics.

Table 4-4 Metrics Provided by an Oracle Hardware System Target
Metric Column
Description
ILOM Address
IP address of the ILOM Service Processor (if connected to network)
ILOM MAC Address
MAC address of the ILOM Service Processor
Chassis Address
IP address of the chassis, only relevant for Blade server modules
Host Primary MAC Address
MAC address of server's primary network interface
Permitted Power Consumption
Actual value of the server's maximum permitted power consumption as configured in the ILOM Service Processor

System Information Metrics

The System Information metrics are collected from an Oracle Hardware System target every 24 hours. The metrics provide an overview of the Oracle Hardware System target's hardware. The following table explains the different metrics.

Table 4-5 System Information Metrics Provided by an Oracle Hardware System Target
Metric Column
Description
Model
Server model identifier
System Type
Rack Mount or Blade
Chassis Model
The chassis that the Blade is in. Only shown on relevant Blades.
Serial Number
System Serial Number
System Identifier
Custom server identifier as configured in the ILOM Service Processor
Processor Architecture
Architecture of installed CPUs, for example x86 64-bit
Processor Summary
Summary of installed CPUs models
System Firmware Version
Summary of installed system firmware, for example BIOS and ILOM

System Inventory Metrics

The System Inventory Metrics are collected from an Oracle Hardware System target every 24 hours. The metrics provide an overview of the hardware in the Oracle Hardware System target. The following table explains the different metrics.

Table 4-6 System Inventory Metrics Provided by an Oracle Hardware System Target
Metric Column
Description
Disk Controllers
The number of detected disk controllers.
Ethernet NICs
The number of detected Ethernet NICs.
Installed Add-on Cards
The number of detected add-on cards.
Installed Chassis Fans
The number of detected chassis fans.
Installed CPUs
The number of detected central processing units.
Installed DIMMs
The number of detected dual in-line memory modules.
Installed Disks
The number of detected disk drives.
Installed Disk Size
The size of the detected disk drives.
Installed FMODs
The number of detected flash modules.
Installed Memory
The size of the total detected memory.
Installed Power Supplies
The number of detected power supplies.
Installed Power Supply Fans
The number of detected power supply fans.
Logical Volumes
The number of logical volumes present.

System Inventory Limits

The System Inventory limits are collected from an Oracle Hardware System target every 24 hours. The limits provide an overview of the maximum hardware amounts that can be installed on the Oracle Hardware System target. The following table explains the different limits.

Table 4-7 System Inventory Limits Provided by an Oracle Hardware System Target
Metric Column
Description
Maximum Chassis Fans
Maximum number of server chassis fans that can be installed in the chassis
Maximum Power Supply Fans
Maximum number of power supply fans that can be installed in the chassis
Maximum CPUs
Maximum number of processors that can be installed in the chassis
Maximum DIMMs
Maximum number of memory modules that can be installed in the chassis
Maximum Power Supplies
Maximum number of power supplies that can be installed in the chassis
Maximum Disks
Maximum number of hard drives that can be installed in the chassis
Maximum FMODs
Maximum number of flash storage modules that can be installed in the chassis