Sun Blade X6240 Server Module Service Manual
820-3971-11
Contents |
1. Introduction to the Sun Blade X6240 Server Module
1.1 Features of the Server Module
1.2 Sun Blade X6240 Server Module Orientation
1.4 Additional Options and Replaceable Components
2. Powering On and Configuring BIOS Settings
2.3.1 Changing the Configuration of a BIOS Menu Item
2.3.2.1 PCI Card Slot Booting Priority
2.3.2.2 Ethernet Port Device and Driver Naming
2.3.2.3 Ethernet Port Booting Priority
2.3.2.4 BIOS Option ROM Size Limitation
2.3.5 BIOS Advanced Menu Screens
2.3.5.1 BIOS Advanced Menu Main Screen
2.3.5.2 BIOS Advanced Menu CPU Configuration Screen
2.3.5.3 BIOS Advanced Menu IDE Configuration Screen
2.3.5.4 BIOS Advanced Menu ACPI Configuration Screen
2.3.5.5 BIOS Advanced Menu Event Logging Details Screen
2.3.5.6 BIOS Advanced Menu IPMI Configuration Screen
2.3.5.7 BIOS Advanced Menu IPMI, LAN Configuration Screen
2.3.5.8 BIOS Advanced Menu IPMI, PEF Configuration Screen
2.3.5.9 BIOS Advanced Menu MPS Configuration Screen
2.3.5.10 BIOS Advanced Menu PCI Express Configuration Screen
2.3.5.11 BIOS Advanced Menu Remote Access Configuration Screen
2.3.5.12 BIOS Advanced Menu Trusted Computing Screen
2.3.5.13 BIOS Advanced Menu USB Configuration Screen
2.3.7.1 BIOS Boot Menu Main Screen
2.3.7.2 BIOS Boot Menu Boot Settings Configuration Screen
2.3.7.3 BIOS Boot Menu Boot Device Priority Screen
2.3.7.4 BIOS Boot Menu Hard Disk Drives Screen
2.3.8 BIOS Security Settings Menu
2.3.9 BIOS Chipset Menu Screens
2.3.9.1 BIOS Chipset Menu Main Screen
2.3.9.2 BIOS Chipset Menu NorthBridge Configuration Screen
2.3.9.3 BIOS Chipset Menu NorthBridge Memory Configuration Screen
2.3.9.4 BIOS Chipset Menu NorthBridge ECC Configuration Screen
2.3.9.5 BIOS Chipset Menu NorthBridge DRAM Timing Configuration Screen
2.3.9.6 BIOS Chipset Menu SouthBridge Configuration Screen
2.3.10 BIOS Exit Option Menu Screen
2.4 Modifying Settings Using Jumpers
2.4.1 Using the Clear CMOS Jumper J16
2.4.2 Resetting SP Password Using Jumper J19
2.4.3 Recovering the SP Using Jumper J21
3.2.1 External Status Indicator LEDs
3.2.2 Internal Status Indicator LEDs
3.3.1 How BIOS POST Memory Testing Works
3.3.2 Redirecting Console Output
3.5 Pc-Check Diagnostics Overview
3.5.1 Accessing Pc-Check Diagnostics
3.6.3.1 To Select and Test a Hard Drive
3.6.4.1 Performing Immediate Burn-In Testing
3.6.4.2 Performing Deferred Burn-In Testing
4. Maintaining the Sun Blade X6240 Servers
4.2 Removing the Server Module From the Chassis and Removing the Cover
4.2.1 Removing the Server Module From the Chassis
4.3 Replaceable Component Procedures
4.3.1 Replacing a Hard Disk Drive
4.3.2 Replacing the System Battery
4.3.3 Replacing the Compact Flash Module
4.3.4 Replacing Memory Modules (DIMMs)
4.3.4.3 Error Correction and Parity
4.3.5 Adding or Replacing a RAID Expansion Module
4.3.5.1 Adding, or Removing and Replacing a REM
4.3.6 Changing the REM Battery
4.3.7 Adding or Replacing a Fabric Expansion Module
4.3.7.1 Adding, or Removing and Replacing a FEM
4.3.8 Replacing a CPU and Heatsink
4.3.9 Replacing the Motherboard
4.4 Servicetool FRU Update Procedure
Copyright © 2009 Sun Microsystems, Inc. All rights reserved.