Replace the Real Time Clock (System) Battery

This is an internal component accessed from the rear of the server by removing the SMOD. Perform this procedure to replace a failed system battery.

Before You Begin

  1. Prepare the server for cold service. See Prepare the Server for Cold Service.
  2. Remove the SMOD. See Remove the SMOD.
  3. Set the SMOD on a flat surface with the back side facing toward you.

    The RTC battery is located on the SMOD motherboard.


    image:An illustration showing the location of the system                                 battery.
  4. To remove the battery, pull it up and out of its holder.
    image:An illustration showing the removal of the system                                 battery.
  5. To orient the replacement battery, ensure that the positive (+) side of the battery is facing the holder.
  6. To install the battery, set it in the holder and push it inward.

    The battery snaps into place.


    image:An illustration showing the installation of the system                                 battery.
  7. Ensure that the battery is properly seated in its holder.

    The battery must be square in the holder.


    Note -  If necessary, once the server is operational, access the BIOS Setup Utility to set the clock

Next Steps