Go to main content

SPARC M8 and SPARC M7 Servers Product Notes

Exit Print View

Updated: January 2022
 
 

Shutting Down Root and I/O Domain On Servers With a Virtual Function and Certain PCIe Cards Can Panic I/O Domain (26138639)

After shutting down an Oracle VM server for SPARC root domain using the –f option (for example, ldm stop -f root domain), shutting down an I/O domain with the ldm stop command causes the I/O domain to panic.

This issue affects servers containing one of the following PCIe cards and a virtual function (VF) assigned to the root domain.

  • Oracle Quad 10Gb or Dual 40Gb Ethernet Adapter

  • Oracle Quad Port 10GBase-T Adapter

Recovery: Reboot the I/O domain.

Workaround: Avoid using the –f option with the ldm command on servers with a VF assigned to the root domain and one of the preceding PCIe cards installed.