Go to main content

Oracle® SuperCluster M8 and SuperCluster M7 Overview Guide

Exit Print View

Updated: March 2020
 
 

Extreme Flash Storage

These are the components in the Extreme Flash version of the storage server:

  • 8 NVMe PCIe 3.0 SSD Extreme Flash disks. Capacities of those Extreme Flash disks vary, depending on the type of storage server:

    • 1.6 TB (X5-2L)

    • 3.2 TB (X6-2L)

    • 6.4 TB (X7-2L)

  • 2 IB 4 X QDR (40 Gb/s) IB ports (1 dual-port PCIe 3.0 HCA)

  • 4 embedded Gigabit Ethernet ports

  • 1 Ethernet port for ILOM for remote management

  • Oracle Linux with Unbreakable Enterprise Kernel 2

  • Oracle Exadata Storage Server Software

This table lists the storage capacities for a single storage server with Extreme Flash drives. To determine the system's total storage server capacity, multiply the single storage server capacity with the total number of storage servers in the system.

Table 1  Single Storage Server Capacity, Extreme Flash Version
Capacity Type
8 x 1.6 TB (X5-2L)
8 x 3.2 TB (X6-2L)
8 x 6.4 TB (X7-2L)
Raw capacity
12.8 TB
25.6 TB
51.2 TB
Usable mirrored capacity (ASM normal redundancy)
5 TB
10 TB
20 TB
Usable triple-mirrored capacity (ASM high redundancy)
4.3 TB
8.6 TB
17.2 TB

Related Information