Go to main content
Oracle® ZFS Storage ZS5-ES Installation Guide, Release OS8.6.x

Exit Print View

Updated: March 2017
 
 

Electrical Power Requirements

The Oracle ZFS Storage ZS5-ES controller uses AC power. The following table lists the power supply specifications for the controller.


Note -  The power dissipation numbers listed in the following table are the maximum rated power numbers for the power supply used in the system. The numbers are not a rating of the actual power consumption of the system.
Table 5  Power Supply Specifications
Parameter
Specification
Voltage (nominal)
100 to 127 VAC; 200 to 240 VAC
Input current (maximum)
7.2 A @ 100-127 VAC; 3.4 A @ 200-240 VAC
Frequency (nominal)
50/60 Hz (47 to 63 Hz range)

The controller can operate effectively over a range of voltages and frequencies. However, it must have a reliable power source. Damage to the controller might occur if the ranges are exceeded. Electrical disturbances such as the following might damage the system:

  • Fluctuations caused by brownouts

  • Wide and rapid variations in input voltage levels or in input power frequency

  • Electrical storms

  • Faults in the distribution system, such as defective wiring

To protect your controller from such disturbances, you should have a dedicated power distribution system, power-conditioning equipment, as well as lightning arresters or power cables to protect from electrical storms.

See the following sections for additional power specifications.